MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.112.970442

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2012

Relevance of electrical remodeling in human atrial fibrillation: results of the Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial mechanisms of atrial fibrillation study.

Healey Jeff S, Israel Carsten W, Connolly Stuart J, Hohnloser Stefan H, Nair Girish M, Divakaramenon Syamkumar, Capucci Alessandro, Van Gelder Isabelle C, Lau Chu-Pak, Gold Michael R, Carlson Mark, Themeles Ellison, Morillo Carlos A

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

In animal models of atrial fibrillation (AF), changes in atrial electrophysiological properties are associated with the development of AF. Their relevance to human AF is unclear.

METHODS AND

RESULTS

The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial enrolled 2580 patients receiving a dual-chamber pacemaker, who were older than the age of 65 and had a history of hypertension, but no history of AF. Serial noninvasive electrophysiological testing was performed over 2 years in a subgroup of 485 patients. There were no differences in the clinical characteristics between patients with and those without device-detected atrial tachyarrhythmias during the first year. Patients with atrial tachyarrhythmias had longer paced (153±29 versus 145±28 ms; P=0.046) and sensed (128±46 versus 118±25 ms; P=0.06) P-wave durations and were more likely to have AF induced during electrophysiological testing (23.5% versus 13.6%; P=0.03). They had similar corrected sinus node recovery times at 90 bpm (388±554 versus 376 ± 466 ms; P=0.86), atrial effective refractory periods at 90 bpm (250±32 versus 248±36 ms; P=0.70), and rate-adaptive shortening of the atrial effective refractory periods (14±13 versus 12±14 ms; P=0.11). There were no significant differences in the change in electrophysiological properties over 2 years between patients with and those without atrial tachyarrhythmias.

CONCLUSIONS

Prolonged P-wave duration, but not differences in atrial effective refractory periods, was associated with the development of atrial tachyarrhythmias in pacemaker patients.

Для цитирования: Healey Jeff S, Israel Carsten W, Connolly Stuart J, Hohnloser Stefan H, Nair Girish M, Divakaramenon Syamkumar, Capucci Alessandro, Van Gelder Isabelle C, Lau Chu-Pak, Gold Michael R, Carlson Mark, Themeles Ellison, Morillo Carlos A. Relevance of electrical remodeling in human atrial fibrillation: results of the Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial mechanisms of atrial fibrillation study.. Circulation. Arrhythmia and electrophysiology. 2012. DOI: 10.1161/circep.112.970442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.