MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2012.03.014

Медицинская библиотека · Heart rhythm · 2012

Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death.

Merchant Faisal M, Ikeda Takanori, Pedretti Roberto F E, Salerno-Uriarte Jorge A, Chow Theodore, Chan Paul S, Bartone Cheryl, Hohnloser Stefan H, Cohen Richard J, Armoundas Antonis A

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Previous studies have demonstrated that microvolt T-wave alternans (MTWA) testing is a robust predictor of ventricular tachyarrhythmias and sudden cardiac death (SCD) in at-risk patients. However, recent studies have suggested that MTWA testing is not as good a predictor of "appropriate" implantable cardioverter-defibrillator (ICD) therapy as it is a predictor of SCD in patients without ICDs.

OBJECTIVE

To evaluate the utility of MTWA testing for SCD risk stratification in patients without ICDs.

METHODS

Patient-level data were obtained from 5 prospective studies of MTWA testing in patients with no history of ventricular arrhythmia or SCD. In these studies, ICDs were implanted in only a minority of patients and patients with ICDs were excluded from the analysis. We conducted a pooled analysis and examined the 2-year risk for SCD based on the MTWA test result.

RESULTS

The pooled cohort included 2883 patients. MTWA testing was positive in 856 (30%), negative in 1627 (56%), and indeterminate in 400 (14%) patients. Among patients with a left ventricular ejection fraction (LVEF) of ≤35%, annual SCD event rates were 4.0%, 0.9%, and 4.6% among groups with MTWA positive, negative, and indeterminate test results. The SCD rate was significantly lower among patients with a negative MTWA test result than in patients with either positive or indeterminate MTWA test results (P <.001 for both comparisons). In patients with an LVEF of >35%, annual SCD event rates were 3.0%, 0.3%, and 0.3% among the groups with MTWA positive, negative, and indeterminate test results. The SCD rate associated with a positive MTWA test result was significantly higher than that associated with either negative (P <.001) or indeterminate MTWA test results (P = .003).

CONCLUSIONS

In patients without ICDs, MTWA testing is a powerful predictor of SCD. Among patients with an LVEF of ≤35%, a negative MTWA test result is associated with a low risk for SCD. Conversely, among patients with an LVEF of >35%, a positive MTWA test result identifies patients at significantly heightened SCD risk. These findings may have important implications for refining primary prevention ICD treatment algorithms.

Для цитирования: Merchant Faisal M, Ikeda Takanori, Pedretti Roberto F E, Salerno-Uriarte Jorge A, Chow Theodore, Chan Paul S, Bartone Cheryl, Hohnloser Stefan H, Cohen Richard J, Armoundas Antonis A. Clinical utility of microvolt T-wave alternans testing in identifying patients at high or low risk of sudden cardiac death.. Heart rhythm. 2012. DOI: 10.1016/j.hrthm.2012.03.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.