Swaans Martin J, Post Martijn C, van der Ven H A Johan, Heijmen Robin H, Budts Werner, ten Berg Jurien M
Аннотация
OBJECTIVE: We describe the short-term results of the patients who underwent transapical treatment of a paravalvular leak (PVL) in our centre.
BACKGROUND: Increasing experience with transapical aortic valve implantation has inspired us to explore this approach for prosthetic paravalvular leak reduction in high risk patients.
METHODS: All procedures were performed in the catheterization laboratory under general anesthesia, using a small anterolateral thoracotomy to expose the apex. Access through a 9-French sheath was necessary to introduce the Amplatzer Vascular III plug. Three-dimensional transesophageal echocardiography (3D-TEE) was used to guide the operator and evaluate the severity of regurgitation postimplantation.
RESULTS: In total seven consecutive patients (mean age 72.8 ± 5.6 years, 86% male) with a history of mitral valve (n = 6) or aortic valve replacement and severe PVL, underwent transapical PVL reduction using seven plugs in total (diameter 10-14 mm). Preprocedural median logistic EuroSCORE was 28.5% (range 17.1-41.1%) and NYHA functional class was ≥3 in all patients. The procedure was successful in all patients, with a median fluoroscopic time of 18.7 min (range 10.1-29.6 min). Postprocedure 3D-TEE showed occlusion of PVL in three patients, and significant reduction in three patients. Postprocedural complication was a hematothorax requiring surgery in one patient. Median hospitalization duration after the procedure was 5 days (range 5-59 days). At 3-month follow-up one patient died, functional class and LDH did not differ significantly and there was a significant increase in hemoglobin.
CONCLUSIONS: Transapical paravalvular leak reduction might be a good or rather attractive alternative in high-risk patients for major re-do cardiac surgery.
BACKGROUND: Increasing experience with transapical aortic valve implantation has inspired us to explore this approach for prosthetic paravalvular leak reduction in high risk patients.
METHODS: All procedures were performed in the catheterization laboratory under general anesthesia, using a small anterolateral thoracotomy to expose the apex. Access through a 9-French sheath was necessary to introduce the Amplatzer Vascular III plug. Three-dimensional transesophageal echocardiography (3D-TEE) was used to guide the operator and evaluate the severity of regurgitation postimplantation.
RESULTS: In total seven consecutive patients (mean age 72.8 ± 5.6 years, 86% male) with a history of mitral valve (n = 6) or aortic valve replacement and severe PVL, underwent transapical PVL reduction using seven plugs in total (diameter 10-14 mm). Preprocedural median logistic EuroSCORE was 28.5% (range 17.1-41.1%) and NYHA functional class was ≥3 in all patients. The procedure was successful in all patients, with a median fluoroscopic time of 18.7 min (range 10.1-29.6 min). Postprocedure 3D-TEE showed occlusion of PVL in three patients, and significant reduction in three patients. Postprocedural complication was a hematothorax requiring surgery in one patient. Median hospitalization duration after the procedure was 5 days (range 5-59 days). At 3-month follow-up one patient died, functional class and LDH did not differ significantly and there was a significant increase in hemoglobin.
CONCLUSIONS: Transapical paravalvular leak reduction might be a good or rather attractive alternative in high-risk patients for major re-do cardiac surgery.
Предметные рубрики MeSH
AgedAortic ValveEchocardiography, Three-DimensionalEchocardiography, TransesophagealEquipment Failure AnalysisFemaleFluoroscopyFollow-Up StudiesHeart Valve DiseasesHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansLogistic ModelsMaleMinimally Invasive Surgical ProceduresMitral ValveNetherlandsPostoperative ComplicationsProsthesis FailureReoperationRisk AssessmentSampling StudiesSurvival AnalysisThoracotomyTreatment OutcomeUnnecessary Procedures