DOI 10.1016/j.urology.2021.08.008
Does Switching Bacillus Calmette-Guerin Strains During Maintenance Therapy Affect the Outcome in Non-Muscle Invasive Bladder Cancer?
Аннотация
OBJECTIVE
To compare the patients who have received 1 type of BCG strain during maintenance therapy with patients treated with multiple BCG strains.
MATERIAL AND
METHODS
We reviewed 279 patients treated with BCG between January 2012 and May 2019, retrospectively. The primary endpoints of the study were recurrence-free survival (RFS) and progression-free survival (PFS) rates among patients receiving same BCG strain (Group-1) and multiple BCG strains (Group-2). Matching analysis was performed to balance the groups. The Kaplan-Meier method was used for estimating RFS and PFS. The difference between the 2 groups in terms of adverse effects was evaluated using the chi-square test.
RESULTS
A total of 225 (80.6 %) patients were treated with single BCG strain, and 54 (19.4 %) were treated with multiple BCG strains. Overall, recurrence and progression was observed in 86 (30.8%) and 38 (13.6%) patients, respectively. There was no significant difference between the 2 groups in terms of recurrence-free survival and progression-free survival on both without matching and with propensity score match analysis (log rank; P=.760 and P=.559, P=.533 and P=0509 for non-match and matched analysis respectively). Most of the patients in both groups experienced BCG therapy related side effects, but there was no statistically significant difference between groups (P=.235/.833).
CONCLUSIONS
Switching the BCG strain because of unavailability of the induction strain does not decrease the effectiveness of the treatment. When it is not possible to reach the starting BCG strain, treatment can be safely continued with any available strain.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.