MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/1061186x.2019.1693577

Медицинская библиотека · Journal of drug targeting · 2019

Engineering and characterisation of BCG-loaded polymeric microneedles.

Arshad Muhammad Sohail, Fatima Sameen, Nazari Kazem, Ali Radeyah, Farhan Muhammad, Muhammad Syed Aun, Abbas Nasir, Hussain Amjad, Kucuk Israfil, Chang Ming-Wei, Mehta Prina, Ahmad Zeeshan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The aim of this study was to fabricate Bacillus Calmette-Guérin (BCG)-loaded microneedle patches using micromould casting technique and compare their efficacy with the injectable counterparts. The microneedle patches were formulated using sodium alginate (10% w/v) and trehalose (20% of polymer). The patches were characterised using optical microscopy, scanning electron microscopy and folding endurance. Serum IgG, TLC, granulocyte count, lymphocyte count and CRP were assessed and results were compared to that of intradermal injections alongside controls. The results showed that polymeric patches had a thickness of 0.8 mm, microneedle projections of 272 ± 12 µm and folding endurance of more than 300. Based on haematological and IgG ELISA assays, microneedle-based BCG administration significantly activated the immune cells and induced production of lymphocytes, granulocytes and peptide-specific IgG in immunised rats that were comparable to injectable counterparts. There was an increase in IgG antibodies from 3 g/L to 5.98 g/L and an increase in leucocytes from 2.6 × 109/L to 18.45 × 109/L. There was also an increase in granulocytes from 14.4% to 29.15% and lymphocyte count from 58.75% to 85.3%. It was concluded that BCG-coated polymeric microneedle patches are suitable for the transdermal delivery of vaccine without inducing discomfort usually observed with injections.

Для цитирования: Arshad Muhammad Sohail, Fatima Sameen, Nazari Kazem, Ali Radeyah, Farhan Muhammad, Muhammad Syed Aun, Abbas Nasir, Hussain Amjad, Kucuk Israfil, Chang Ming-Wei, Mehta Prina, Ahmad Zeeshan. Engineering and characterisation of BCG-loaded polymeric microneedles.. Journal of drug targeting. 2019. DOI: 10.1080/1061186x.2019.1693577.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.