Inhalation Profiles Through a Dry Powder Inhaler: Relation Between Inhalation Technique and Spirometric Measures.
Аннотация
Background
The understanding of the real flow profiles through a dry powder inhaler (DPI), generated by asthma patients, is a prerequisite for satisfactory drug delivery to the lungs. The aims of the study were to assess the relationship between spirometric measures and inhalation profiles through a low-resistance DPI, and to compare parameters of those profiles between optimal and suboptimal inhalation technique type.
Methods
Both healthy adult volunteers and patients with asthma were included in the study. Spirometry was conducted along with modified flow-volume test to detect expiratory levels (maximum "100%" exhalation to residual volume [RV] and halfway "50%" to RV). These were the reference levels of the depth of exhalation for each patient to simulate the effect of incomplete exhalation. Individual inhalation profiles were recorded using spirometry in-house software as the volumetric airflow through the inhaler versus time. Inspiratory flow parameters were extracted: time to peak inspiratory flow through inhaler (PIFinh), time at which peak inspiratory flow occurs (tPIFinh), total inhalation time (T), and inhaled volume during maneuver (V). Results and
Conclusions
There are significant relationships between spirometric indices and parameters of inhalation through a low-resistance, cyclohaler-type DPI (assessed by single-factor analysis of Spearman's rank correlation coefficient). Multiple regression models were constructed, predicting inspiratory flow parameters (including spirometric indices, demographic parameters, and inhaler's usage history as determinants). The exhalation halfway to RV before inhalation did not affect significantly PIFinh and tPIFinh (and, thus, initial flow dynamics) in asthma patients. T and V parameters were then significantly decreased, but seemed sufficient for successful DPI performance. Both exhalation to RV and incomplete exhalation halfway to RV preceding inhalation allow for effective usage of low-resistance DPI.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.