MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsomega.4c04460

Медицинская библиотека · ACS omega · 2024

Dual-Target Additively Manufactured Electrochemical Sensor for the Multiplexed Detection of Protein A29 and DNA of Human Monkeypox Virus.

Silva Luiz Ricardo G, Stefano Jéssica S, Kalinke Cristiane, Crapnell Robert D, Brazaca Laís C, Marcolino-Junior Luiz H, Bergamini Marcio F, Banks Craig E, Janegitz Bruno C

СтатьяПеревод в очереди

Аннотация

Herein, we present the first 3D-printed electrochemical portable biodevice for the detection of monkeypox virus (MKPV). The electrochemical device consists of two biosensors: an immunosensor and a genosensor specifically designed for the detection of the protein A29 and a target DNA of MKPV, respectively. The electrodes were manufactured using lab-made ultraflexible conductive filaments composed of carbon black, recycled PLA from coffee pods, and castor oil as a plasticizer. The sensors created through 3D printing technology exhibited good reproducibility and repeatability of analytical responses. Furthermore, both the immunosensor and genosensor demonstrated excellent MKPV detection capabilities, with a linear range from 0.01 to 1.0 μmol L-1 for the antigen and 0.1 to 20.0 μmol L-1 for the DNA target. The biosensors achieved limits of detection of 2.7 and 29 nmol L-1 for the immunosensor and genosensor, respectively. Interference tests conducted with the biosensors demonstrated their selectivity for MKPV. Moreover, analyses of fortified human serum samples showed recoveries close to 100%, confirming the absence of significant matrix effects for MKPV analysis. Therefore, the 3D-printed multiplex device represents a viable and highly promising alternative for on-site, portable, and rapid point-of-care MKPV monitoring.

Для цитирования: Silva Luiz Ricardo G, Stefano Jéssica S, Kalinke Cristiane, Crapnell Robert D, Brazaca Laís C, Marcolino-Junior Luiz H, Bergamini Marcio F, Banks Craig E, Janegitz Bruno C. Dual-Target Additively Manufactured Electrochemical Sensor for the Multiplexed Detection of Protein A29 and DNA of Human Monkeypox Virus.. ACS omega. 2024. DOI: 10.1021/acsomega.4c04460.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.