MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2000-9573

Медицинская библиотека · Klinische Monatsblatter fur Augenheilkunde · 2000

[Acute retinal necrosis syndrome: analysis, therapy and long-term follow up of 14 eyes].

Müller B, Velhagen K H, Pleyer U

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE: Acute retinal necrosis syndrome (ARN) might be complicated by retinal detachment, vasculopathy and optic neuropathy and has a poor prognosis despite intensive medical and surgical therapy.

PATIENTS AND

METHODS

A series of 10 consecutive patients (14 eyes) with ARN were followed for 36 months (average of 20 months +/- 10). We present the results of the clinical evaluation for diagnostic and therapeutic modalities.

RESULTS

Viral etiology was confirmed in 9 of 10 aqueous-humor samples. Intraocular antibody synthesis against Varicella-Zoster Virus was found in 7, against Herpes-Simplex Virus in 5 and against Cytomegalovirus in 2 samples. Three eyes had a mild clinical course with a visual acuity of 0.6 or better. Vitrectomy and silicone-oil tamponade preserved visual acuity from 0.3 to 0.1. ARN lead to blindness in 5 eyes due to vasculopathy, optic neuropathy or retinal detachment. An arterial branch occlusion was successfully overcome with i.v. heparin treatment in one patient.

CONCLUSION

Aqueous-humor analysis supports clinical diagnosis. Early vitrectomy and silicone oil tamponade stabilizes retinal structure and preserves visual acuity. Occlusive vasculopathy and optic neuropathy are the main causes leading to blindness.

Для цитирования: Müller B, Velhagen K H, Pleyer U. [Acute retinal necrosis syndrome: analysis, therapy and long-term follow up of 14 eyes].. Klinische Monatsblatter fur Augenheilkunde. 2000. DOI: 10.1055/s-2000-9573.