m+Medelevator.RU
← Поиск публикаций
The Journal of urology · 2010

Safety and efficacy of intravesical bacillus Calmette-Guérin plus interferon α-2b therapy for nonmuscle invasive bladder cancer in patients with prosthetic devices.

Клиническое исследование II фазыСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rosevear Henry M, Lightfoot Andrew J, Nepple Kenneth G, O'Donnell Michael A

Аннотация

PURPOSE: Patients with bladder cancer who have prosthetic devices, such as a cardiac pacemaker, artificial heart valve or orthopedic hardware, and who undergo intravesical bacillus Calmette-Guérin therapy are theoretically at higher risk for complications, including bacterial seeding of pacemaker wires or orthopedic hardware, and at further risk for infective endocarditis. We assessed the safety and efficacy of bacillus Calmette-Guérin plus interferon α-2b therapy in patients with nonmuscle invasive bladder cancer and a pacemaker, artificial heart valve or orthopedic hardware.

MATERIALS AND METHODS: We evaluated 1,045 patients with nonmuscle invasive bladder cancer enrolled in a multicenter American phase II trial of bacillus Calmette-Guérin plus interferon α-2b therapy, including 143 with a prosthetic device (pacemaker in 87, artificial heart valve in 13 and orthopedic hardware in 43). Weekly physician toxicity assessments and standard adverse effect reporting were done.

RESULTS: No patient had infective endocarditis or hardware infection. One patient with a pacemaker, 2 with orthopedic hardware and none with an artificial heart valve required treatment cessation for fever greater than 102.5F. All defervesced within 24 hours and had no long-term sequelae. Due to intolerable, nonlife threatening side effects 12 patients with a pacemaker, 2 with orthopedic hardware and 1 with an artificial heart valve stopped treatment. Of the remaining patients with a prosthesis 99 and 24 stopped treatment due to intolerable, nonlife threatening and serious side effects, respectively.

CONCLUSIONS: Patients with a pacemaker, artificial heart valve or orthopedic hardware were no more likely than the general population to have infection or fever, or discontinue treatment due to side effects. These patients should not be excluded from intravesical bacillus Calmette-Guérin plus interferon α-2b therapy for nonmuscle invasive bladder cancer.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты