MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urology.2010.06.052

Медицинская библиотека · Urology · 2010

Use of the valveless trocar system reduces carbon dioxide absorption during laparoscopy when compared with standard trocars.

Herati Amin S, Andonian Sero, Rais-Bahrami Soroush, Atalla Mohamed A, Srinivasan Arun K, Richstone Lee, Kavoussi Louis R

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

To prospectively compare a novel type of valveless trocar that creates a curtain of pressurized carbon dioxide [CO(2)] gas (which maintains pneumoperitoneum at a lower gas flow rate) with standard trocars; to quantify the volume of CO(2) used; and to characterize CO(2) elimination during laparoscopic renal surgery.

METHODS

A total of 51 patients undergoing laparoscopic renal surgery by a single surgeon were prospectively evaluated using either the valveless trocar (n = 26) or standard trocars (n = 25). Patient demographics, operative time, volume of CO(2) gas consumed, CO(2) elimination, perioperative parameters, and postoperative complications were recorded and analyzed.

RESULTS

Both patient cohorts were comparable in their preoperative demographics, including body mass index, the number of patients with chronic obstructive pulmonary disease, and smoking history. Mean operative time was lower in the valveless trocar cohort (124.1 minutes) compared with the conventional trocar group (145.6 minutes), P = .047. Use of the valveless trocar was associated with a lower volume of intraoperative CO(2) consumed (120.0 ± 82.8 vs 300.6 ± 191.5; P < .001) and reduced CO(2) elimination compared with standard trocar use after the first 16 minutes of insufflation (P < .05). Minimal complications occurred, including 2 cases of subcutaneous emphysema in the valveless trocar group, and 1 case of respiratory acidosis in the conventional trocar group.

CONCLUSIONS

Use of a valveless trocar significantly reduced CO(2) consumption during transperitoneal laparoscopy. The valveless trocar also demonstrated significantly reduced CO(2) elimination and absorption when compared with the standard trocar.

Для цитирования: Herati Amin S, Andonian Sero, Rais-Bahrami Soroush, Atalla Mohamed A, Srinivasan Arun K, Richstone Lee, Kavoussi Louis R. Use of the valveless trocar system reduces carbon dioxide absorption during laparoscopy when compared with standard trocars.. Urology. 2010. DOI: 10.1016/j.urology.2010.06.052.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.