Friedman Michael, Schalch Paul, Vidyasagar Ramakrishnan, Kakodkar Kedar A, Mazloom Narges, Joseph Ninos J
Аннотация
OBJECTIVES: To confirm feasibility of transnasal placement of a wireless pH-monitoring capsule in the upper esophagus, and to determine the positive predictive value of LPR and GERD signs and symptoms for diagnosis of LPR in patients with OSAHS.
STUDY DESIGN: Prospective, nonrandomized, IRB-approved study of 89 OSAHS patients with and without symptoms and signs of LPR.
METHODS: After complete history including QOL survey and fiberoptic laryngoscopy, patients underwent transnasal placement of the pH-monitoring capsule and wireless data collection for 24 hours.
RESULTS: 77 of 89 consecutive patients underwent successful placement of wireless pH-monitoring capsule (86.5% success rate) and completed the study. 55 (71.4%) OSAHS patients had positive pH studies. 10.4% of these patients reported no symptoms or signs of LPR, indicating occult disease.
CONCLUSION: Success rates of placement, tolerability, morbidity, and complications are excellent. Wireless upper esophageal pH monitoring is safe and effective for diagnosing LPR in patients with OSAHS.
STUDY DESIGN: Prospective, nonrandomized, IRB-approved study of 89 OSAHS patients with and without symptoms and signs of LPR.
METHODS: After complete history including QOL survey and fiberoptic laryngoscopy, patients underwent transnasal placement of the pH-monitoring capsule and wireless data collection for 24 hours.
RESULTS: 77 of 89 consecutive patients underwent successful placement of wireless pH-monitoring capsule (86.5% success rate) and completed the study. 55 (71.4%) OSAHS patients had positive pH studies. 10.4% of these patients reported no symptoms or signs of LPR, indicating occult disease.
CONCLUSION: Success rates of placement, tolerability, morbidity, and complications are excellent. Wireless upper esophageal pH monitoring is safe and effective for diagnosing LPR in patients with OSAHS.