Chest · 1998
Maximum cardiac output during incremental exercise by first-pass radionuclide ventriculography.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Maroni J M, Oelberg D A, Pappagianopoulos P, Boucher C A, Systrom D M
Аннотация
STUDY OBJECTIVE: To validate a noninvasive first-pass radionuclide ventriculographic (FPRV) measurement of maximum cardiac output (Qv) during exercise.
DESIGN: Comparison of Qv to that measured by the Fick principle (Qf) at peak exercise.
SETTING: Academic cardiopulmonary exercise laboratory.
PATIENTS: Seventy-eight consecutive patients without a history of septal defect undergoing clinically indicated maximum incremental cardiopulmonary exercise testing with pulmonary arterial catheterization and FPRV.
MEASUREMENTS AND RESULTS: Ventilation and gas exchange were measured breath-by-breath or by a mixing chamber/mass spectrometer system. Arterial and mixed venous O2 content were measured each minute during exercise. When patients without left-to-right ventricular stroke count ratio evidence for left-sided regurgitation were isolated, peak Qv was linearly related to Qf (r=0.75, p=0.0001). To account for a small systematic overestimation (bias) of Qf by Qv, the linear equation for the Qv/Qf relation was derived for patients studied between 1990 and 1993 and applied to those studied subsequently. The resulting corrected peak Qv was tightly related to peak Qf (r=0.90, p<0.001) with confidence intervals for slope and intercept overlapping identity.
CONCLUSION: FPRV can reasonably estimate maximum cardiac output during incremental exercise in patients for whom the technique has ruled out left-sided cardiac regurgitant lesions.
DESIGN: Comparison of Qv to that measured by the Fick principle (Qf) at peak exercise.
SETTING: Academic cardiopulmonary exercise laboratory.
PATIENTS: Seventy-eight consecutive patients without a history of septal defect undergoing clinically indicated maximum incremental cardiopulmonary exercise testing with pulmonary arterial catheterization and FPRV.
MEASUREMENTS AND RESULTS: Ventilation and gas exchange were measured breath-by-breath or by a mixing chamber/mass spectrometer system. Arterial and mixed venous O2 content were measured each minute during exercise. When patients without left-to-right ventricular stroke count ratio evidence for left-sided regurgitation were isolated, peak Qv was linearly related to Qf (r=0.75, p=0.0001). To account for a small systematic overestimation (bias) of Qf by Qv, the linear equation for the Qv/Qf relation was derived for patients studied between 1990 and 1993 and applied to those studied subsequently. The resulting corrected peak Qv was tightly related to peak Qf (r=0.90, p<0.001) with confidence intervals for slope and intercept overlapping identity.
CONCLUSION: FPRV can reasonably estimate maximum cardiac output during incremental exercise in patients for whom the technique has ruled out left-sided cardiac regurgitant lesions.