The international journal of tuberculosis and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease · 2001
Performance of whole blood IFN-gamma test for tuberculosis diagnosis based on PPD or the specific antigens ESAT-6 and CFP-10.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Brock I, Munk M E, Kok-Jensen A, Andersen P
Аннотация
OBJECTIVE: To evaluate the QuantiFERON-TB test in BCG-vaccinated, non-BCG-vaccinated and tuberculosis (TB) patient donor groups, and to compare its diagnostic performance with that of a blood test based on the Mycobacterium tuberculosis specific antigens ESAT-6 and CFP-10.
DESIGN: Analysis of the IFN-gamma responses of whole blood cells from BCG-vaccinated or non-BCG-vaccinated donors or patients with tuberculosis, stimulated with PPD, ESAT-6 or CFP-10 antigens, and evaluation of the specificity and sensitivity of the test.
RESULTS: None of the non-vaccinated donors showed positive responses to M. tuberculosis-PPD, ESAT-6 or CFP-10. In BCG-vaccinated donors, 9/19 (47%) donors responded to the QuantiFERON-TB test based on M. tuberculosis-PPD, whereas 2/19 (10.5%) responded to either ESAT-6 or CFP-10. Comparable levels of sensitivity were obtained with the QuantiFERON-TB test based on M. tuberculosis-PPD (79%) and ESAT-6 or CFP-10 antigens (72%).
CONCLUSION: Our results demonstrate that the whole blood test based on M. tuberculosis-PPD did not efficiently distinguish BCG-vaccinated donors from individuals with disease due to M. tuberculosis. The introduction of new recombinant antigens specific for M. tuberculosis, such as ESAT-6 or CFP-10, should increase the specificity of the whole blood test and enable discrimination between TB infection, atypical mycobacterial reactivity and reactivity due to BCG vaccination. Such a test would provide a quantum improvement over the current practice of using the tuberculin skin test for TB control and elimination.
DESIGN: Analysis of the IFN-gamma responses of whole blood cells from BCG-vaccinated or non-BCG-vaccinated donors or patients with tuberculosis, stimulated with PPD, ESAT-6 or CFP-10 antigens, and evaluation of the specificity and sensitivity of the test.
RESULTS: None of the non-vaccinated donors showed positive responses to M. tuberculosis-PPD, ESAT-6 or CFP-10. In BCG-vaccinated donors, 9/19 (47%) donors responded to the QuantiFERON-TB test based on M. tuberculosis-PPD, whereas 2/19 (10.5%) responded to either ESAT-6 or CFP-10. Comparable levels of sensitivity were obtained with the QuantiFERON-TB test based on M. tuberculosis-PPD (79%) and ESAT-6 or CFP-10 antigens (72%).
CONCLUSION: Our results demonstrate that the whole blood test based on M. tuberculosis-PPD did not efficiently distinguish BCG-vaccinated donors from individuals with disease due to M. tuberculosis. The introduction of new recombinant antigens specific for M. tuberculosis, such as ESAT-6 or CFP-10, should increase the specificity of the whole blood test and enable discrimination between TB infection, atypical mycobacterial reactivity and reactivity due to BCG vaccination. Such a test would provide a quantum improvement over the current practice of using the tuberculin skin test for TB control and elimination.