MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1006/biol.2000.0252

Медицинская библиотека · Biologicals : journal of the International Association of Biological Standardization · 2000

Development and validation of a detection system for wild-type Vibrio cholerae in genetically modified cholera vaccine.

Studer E, Candrian U

СтатьяПеревод в очереди

Аннотация

Orochol, a live oral cholera vaccine licensed in Switzerland and in other countries, is based on the genetically modified Vibrio cholerae strain CVD103-HgR. This strain is derived from the wild-type O1 strain Inaba 569B by deletion of a fragment internal to the ctxA gene encoding the A1 subunit of cholera toxin and by replacement of an internal fragment of the hlyA gene with a fragment carrying the mer operon mediating mercury resistance. In this study we describe a polymerase chain reaction (PCR) system for the detection of wild-type Vibrio cholerae and the identification of the vaccine strain for the quality control of production batches. A multiplex PCR system that targets the intact ctxA gene of the wild-type strain and simultaneously the integration site of the mer operon in the hlyA gene (hlyA::mer) of the vaccine strain CVD103-HgR was developed. To evaluate the detection limit of the system, vaccine suspensions were artificially contaminated with wild-type V. cholerae 569B cells and tested by PCR. The detection limit of the system was statistically evaluated and found to be at 11625 wild-type cells per vaccine sachet (95% confidence limit). This number is below the infective dose of wild-type Vibrio cholerae. In Switzerland this test is used in combination with other tests in the official batch-release procedure to assure the safety of each batch of the cholera vaccine Orochol.

Для цитирования: Studer E, Candrian U. Development and validation of a detection system for wild-type Vibrio cholerae in genetically modified cholera vaccine.. Biologicals : journal of the International Association of Biological Standardization. 2000. DOI: 10.1006/biol.2000.0252.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.