Аннотация

OBJECTIVES

To report longitudinal prevalence rates of device-related pressure injuries in critically ill adult patients in the intensive care unit and to explore the patient characteristics associated with the development of device related pressure injuries.

RESEARCH

DESIGN

A prospective observational design where observations of patients' skin integrity were conducted on one day each week for 52 weeks.

SETTING

The study was conducted in the 36-bed intensive care unit of a major metropolitan tertiary referral hospital in Queensland, Australia. The sample included all patients aged 18 years or older admitted to the intensive care unit before midnight on the day preceding the observation, with a medical device in situ.

MAIN OUTCOME MEASURES: The primary outcome measure was device related pressure injuries identified at the weekly observations and defined as a pressure injury found on the skin or mucous membrane with a history of medical device in use at the location of the injury. Patient demographic and clinical characteristics were recorded.

RESULTS

Over the study period, 11.3% (71/631) of patients developed at least one hospital-acquired DRPI. The most common devices associated with injury were nasogastric/nasojejunal tubes (41%) and endotracheal tubes (27%). Significant predictors of device related pressure injuries were the total number of devices (OR 1.230, 95% CI 1.09-1.38, p < 0.001), the length of time in the ICU (OR 1.05, 95% CI 1.02-1.09, p = 0.003), male sex, (OR 2.099, 95% CI 1.18-3.7, p = 0.012), and increased severity of illness score on admission (OR 1.044, 95% CI 1.01-1.09, p = 0.013).

CONCLUSION

Device related pressure injuries are an all-too-common iatrogenic problem for this vulnerable patient cohort.

Для цитирования: Coyer Fiona, Cook Jane-Louise, Doubrovsky Anna, Vann Amanda, McNamara Greg. Exploring medical device-related pressure injuries in a single intensive care setting: A longitudinal point prevalence study.. Intensive & critical care nursing. 2021. DOI: 10.1016/j.iccn.2021.103155.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.