MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12885-024-13213-6

Медицинская библиотека · BMC cancer · 2024

A randomized trial of MONOFIX® vs. V-loc™ for resection bed suture during robotic partial nephrectomy.

Han Jang Hee, Jung Gyoohwan, Kim Jung Kwon, Byun Seok-Soo, Seo Seong Ii, Hong Sung-Hoo, Kwak Cheol, Jeong Chang Wook

СтатьяРандомизированное исследованиеМногоцентровое исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

To evaluate the clinical efficacy and safety of Monofix®-PDO compared to V-Loc™ for tumor bed suturing during robotic-assisted laparoscopic partial nephrectomy (RAPN).

METHODS

A randomized, controlled, multicenter, single-blinded trial was conducted across four tertiary institutions. Patients with T1-2 stage renal masses scheduled for RAPN were enrolled. The exclusion criteria included patients not deemed in need of bed suturing, those with a history of prior chemotherapy or immunotherapy, and those with severe systemic diseases or high bleeding tendencies. A total of 174 patients participated and were subjected to permuted block randomization (T1a vs. others), resulting in 88 patients in the V-Loc™ group and 86 in the Monofix®-PDO group. The primary outcome was the resection bed suture time. The secondary outcomes were total suture use time, warm ischemia time, console time (for efficacy), estimated blood loss, hemoglobin change, and 90-day treatment-related adverse events (for safety). All patients were scheduled for follow-up visits for up to three months postoperatively.

RESULTS

The primary outcome, resection bed suture time, did not significantly differ between the V-Loc™ and Monofix®-PDO groups (4.8 ± 2.6 vs. 4.5 ± 2.6 min, p = 0.531). Secondary outcomes, including total suture used time (5.3 ± 2.8 vs. 4.8 ± 2.6 min, p = 0.289) and warm ischemic time (15.6 ± 5.5 vs. 15.4 ± 5.4 min, p = 0.834), were comparable between the two groups. In terms of safety outcomes, changes in serum hemoglobin levels did not show significant differences on postoperative days 1, 3, and 14 (P = 0.537, 0.353, and 0.840, respectively). No device-related adverse events were observed during the 90-day follow-up period in either group.

CONCLUSIONS

Monofix®-PDO demonstrated non-inferior to V-Loc in terms of both safety and efficacy in patients undergoing RAPN. This trial is registered on cris.nih.go.kr as KCT0006809 (Registration date: 02/19/2021).

Для цитирования: Han Jang Hee, Jung Gyoohwan, Kim Jung Kwon, Byun Seok-Soo, Seo Seong Ii, Hong Sung-Hoo, Kwak Cheol, Jeong Chang Wook. A randomized trial of MONOFIX® vs. V-loc™ for resection bed suture during robotic partial nephrectomy.. BMC cancer. 2024. DOI: 10.1186/s12885-024-13213-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.