DOI 10.1016/j.talanta.2026.129462
Sensitive lateral flow immunoassay based on the use of Au@Pt nanozyme and aptamer-captured oriented antibodies for the detection of anti-Müllerian hormone.
Аннотация
The application of core@shell nanozymes as labeling materials integrating catalytic amplification with molecular recognition in immunoassay platforms is a challenging task, since antibody immobilization often reduces both antibody reactivity and nanozyme catalytic activity. In this work, an approach to the oriented immobilization of antibodies on the surface of Au@Pt nanozymes using an aptamer specific to the fragment crystallizable region of mouse immunoglobulin G is proposed. This approach ensures that the antigen-binding domains of antibodies remain fully accessible while preserving the peroxidase-mimicking activity of the Au@Pt nanoparticles. Using oriented immobilization approach, we developed lateral flow immunoassay for sensitive detection of anti-Müllerian hormone. The sandwich immunoassay format was implemented using a pair of monoclonal antibodies that recognize different epitopes of the antigen. In this work, three approaches to conjugation, including physical adsorption, covalent and oriented immobilization to form conjugate of monoclonal antibodies with Au@Pt nanozyme, were implemented and compared in lateral flow immunoassay. The peroxidase-like properties of the nanozyme provided enhanced coloration in the test zone of the strip as a result of a catalyzed transformation with the substrate. Due to the combined effect of the high catalytic efficiency of the Au@Pt nanoparticles and the oriented immobilization of monoclonal antibodies on the surface of the nanozyme, an ultra-low detection limit of 30 pg/mL with a detection range from 0.9 to 48 ng/mL was achieved for the detection of anti-Müllerian hormone. Nanozyme-based lateral flow immunoassay allowed to reduce the detection limit by 13 times compared to common gold nanoparticle-based lateral flow immunoassay. In addition, nanozyme-based lateral flow immunoassay, including the subsequent enhancing catalytic reaction step, takes 20 min and is easy to perform. The applicability of the developed lateral flow immunoassay for the determination of anti-Müllerian hormone was confirmed by testing serum samples and revealed good recovery rates. Thus, the high analytical performance of the proposed lateral flow immunoassay demonstrates potential for anti-Müllerian hormone testing in point-of-care conditions. Moreover, the oriented immobilization of antibodies in the detection probe via the aptamer can be used as a versatile tool to improve the sensitivity of different lateral flow immunoassays.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.