MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/07853890.2026.2615487

Медицинская библиотека · Annals of medicine · 2026

Comparative analysis of three different serum-free light chain assays in the diagnosis of multiple myeloma.

Cui Facai, Wang Jinlin, Chen Xiao, Niu Yaxuan, Hu Min, Liu Fengzhen, Li Hanxiao

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The lack of analysis methods and standardization are the core problems of serum free light chain (sFLC) detection in Multiple myeloma (MM). This study validated a new KHB sFLC assay through comparative analysis with conventional assays.

MATERIALS AND

METHODS

Serum samples from 97 hospitalized MM patients were continuously collected. KHB, Freelite and N Latex assays were used to detect sFLC. The Bland-Altman and Passing-Bablok regressions were used for methodological comparison and bias evaluation. Spearman's test and Cohen's kappa coefficients were used to evaluate the correlation and clinical concordance.

RESULTS

The sFLC results for KHB, Freelite, and N Latex showed a significant correlation. Passing-Bablok regression analysis revealed strong concordance between the KHB and N Latex for κFLC, and between KHB and Freelite assays for λFLC and FLC-ratio (κ/λ). When using N Latex and Freelite assays for sFLC determination, selecting iFLC/niFLC ≥ 20 or iFLC/niFLC ≥ 100 could lead to different clinical treatment decisions for approximately 9%∼12% of patients. When using KHB and Freelite assays for sFLC determination, selecting iFLC/niFLC ≥ 20 or iFLC/niFLC ≥ 100 could lead to different clinical treatment decisions for approximately 5%∼7% of patients.

CONCLUSION

KHB, as a sFLC detection method based on polyclonal antibodies and immunoturbidimetric principles, has a good correlation between its detection results and freelite and N Latex. The absolute difference in sFLC results among the three assays increased with increasing sFLC concentration, and selecting the same cutoff value for iFLC/niFLC may lead to inconsistent clinical treatment decisions in some patients.

Для цитирования: Cui Facai, Wang Jinlin, Chen Xiao, Niu Yaxuan, Hu Min, Liu Fengzhen, Li Hanxiao. Comparative analysis of three different serum-free light chain assays in the diagnosis of multiple myeloma.. Annals of medicine. 2026. DOI: 10.1080/07853890.2026.2615487.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.