Integrated Multi-Sensor Assessment System for Objective Muscle Recovery Monitoring: Application of Isokinetic Dynamometry, Infrared Thermometry, and Multi-Biomarker ELISA in Exercise-Induced Muscle Damage Surveillance.

Rhi Soungyob, Sin Bonggeun

СтатьяПеревод в очереди

Аннотация

Purpose: This study aimed to develop and validate a comprehensive multi-sensor integrated platform for objective assessment of skeletal muscle recovery kinetics following exercise-induced muscle damage (EIMD), combining biomechanical, thermal, and biochemical monitoring modalities.

Methods

Forty elite male athletes were randomized to microwave diathermy (MWD, n = 20, 2.45 GHz, 160 W, 45 min/session) or control (n = 20) groups. Time-synchronized multi-sensor assessments at baseline, 24 h, 48 h, and 72 h post-EIMD included: biomechanical sensors (knee flexion range of motion via goniometry and isokinetic peak torque), thermal sensor (skin surface temperature via infrared thermometry), and biochemical sensor array (serum CK, IL-6, and CRP via high-sensitivity ELISA). Two-way repeated-measures ANOVA with Bonferroni correction examined group × time interactions across all sensor channels.

Results

Pre-study validation confirmed high reliability across all sensor modalities. Cross-modality concordance analysis revealed significant correlations between biomechanical and biochemical recovery trajectories (isokinetic torque vs. IL-6: r = -0.73, p < 0.001; pain vs. IL-6: r = 0.68, p < 0.001). MWD intervention demonstrated accelerated recovery across all sensor channels: complete ROM recovery by 48 h (MWDG post-2 vs. baseline, p > 0.05; CG post-3 43% below baseline, p < 0.001), complete isokinetic torque restoration by 72 h (MWDG post-3 vs. baseline, p > 0.05; CG 44% below baseline, p < 0.001), and near-complete pain resolution (VAS 1.70 ± 2.50 mm, p < 0.05). Biomarker sensors demonstrated differential recovery kinetics: IL-6 normalized by 48 h (1.52 ± 0.14 pg/mL, p > 0.05 vs. baseline), CRP approached baseline by 72 h (0.73 ± 0.24 mg/L, p > 0.05), while CK remained elevated at post-3 (169.70 ± 22.58 U/L, 30% above baseline, p < 0.001), indicating incomplete myofiber membrane integrity recovery despite resolution of systemic inflammatory markers. The control group exhibited persistent deficits across all sensor channels with no clinically meaningful recovery.

Conclusions

This study validated an integrated multi-sensor platform for recovery assessment. Microwave diathermy demonstrated efficacy by 72 h with complete functional recovery and inflammatory normalization (though CK remained elevated). Cross-modality concordance (r = -0.73 to 0.68) confirmed superior assessment compared to single-modality approaches. This laboratory-based methodology provides a framework for future portable sensor systems in athletic surveillance.

Для цитирования: Rhi Soungyob, Sin Bonggeun. Integrated Multi-Sensor Assessment System for Objective Muscle Recovery Monitoring: Application of Isokinetic Dynamometry, Infrared Thermometry, and Multi-Biomarker ELISA in Exercise-Induced Muscle Damage Surveillance.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26134215.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.