MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/arj.70226

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026

Damaging Noise Levels Are Seen in Arthroscopic Surgery.

Popper Hannah R, Baker William, Fliegel Brian, Kwan Stephanie, Sherman Matthew, Austin Luke, Salvo John

СтатьяПеревод в очереди

Аннотация

PURPOSE: To determine whether orthopaedic surgeons performing arthroscopic shoulder, hip, and knee surgeries are exposed to damaging noise levels, while also comparing noise levels between these different arthroscopic procedures and further analyzing common arthroscopic knee procedures such as meniscectomy and anterior cruciate ligament reconstruction.

METHODS

A retrospective review was conducted using prospectively collected intraoperative audio measurements during arthroscopic procedures from March 2021 to February 2023. Metrics included the maximum decibel (dB) level (MDL), time-weighted average (TWA), dose, and projected dose. The MDL is the greatest level of noise during each case, TWA is the average dB level over an 8-hour period, dose is the percentage of allowable daily noise, and projected dose extrapolates exposure over 8 hours.

RESULTS

Out of 124 recordings (13 baseline, 111 procedural-10 hip, 40 shoulder, and 61 knee), MDL exceeded >85 dB for all procedures, highest for shoulder procedures (117.5 dB, P < .001). The TWA remained <85 dB for all procedures, which was higher for hip procedures at 62.5 dB (P = .329).

CONCLUSIONS

While TWA levels stay below high-risk thresholds, MDL frequently surpasses 85 dB, indicating potential harmful exposure. Hip arthroscopy trended higher noise levels compared with shoulder and knee arthroscopy.

CLINICAL RELEVANCE: Cumulative exposure to the increased noise during arthroscopic procedures put high volume arthroscopic surgeons at risk for noise-induced hearing loss.

Для цитирования: Popper Hannah R, Baker William, Fliegel Brian, Kwan Stephanie, Sherman Matthew, Austin Luke, Salvo John. Damaging Noise Levels Are Seen in Arthroscopic Surgery.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2026. DOI: 10.1002/arj.70226.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.