INTRODUCTION

Medial pivot total knee arthroplasty (TKA) was developed to reproduce native knee kinematics and improve function. Second-generation designs introduced refinements to enhance medial conformity and lateral rollback, but their clinical benefit remains uncertain. This systematic review compared outcomes of first- and second-generation medial pivot implants.

METHODS

A comprehensive search of PubMed, Web of Science, Embase, and Google Scholar was performed in August 2025 following PRISMA guidelines. Comparative and non-comparative studies reporting outcomes after first- or second-generation medial pivot TKA were included. Primary endpoints were Knee Society Score (KSS), functional subscale (KSS-F), Oxford Knee Score (OKS), WOMAC, Forgotten Joint Score (FJS), range of motion (ROM), and revision rates.

RESULTS

Twenty-four studies including 4686 patients (3541 first-generation; 1145 s-generation) were analysed. Most baseline variables were comparable, though BMI, follow-up duration, and baseline WOMAC and ROM showed minor differences. At the latest follow-up, KSS, KSS-F, WOMAC, and FJS showed no significant differences. Revision rates were similar. OKS was slightly lower in the second-generation cohort (MD -2.5, p = 0.04), and ROM was greater (MD 4.6°, p = 0.01), but both fell below minimal clinically important difference thresholds.

CONCLUSION

First- and second-generation medial pivot TKAs achieved comparable outcomes and survivorship. Although second-generation designs showed statistical improvements in ROM and OKS, these were not clinically relevant. These findings suggest that while design refinements of second-generation implants may offer minor biomechanical advantages, they do not translate into significant improvements in patient-reported outcomes. Surgical decision-making should be based on the surgeon's experience, implant availability, and patient-specific factors rather than expectations of superior performance from newer designs.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Migliorini Filippo, Pilone Marco, Schäfer Luise, Vaishya Raju, Memminger Michael, Maffulli Nicola. Impact of implant generation on the outcomes in medial pivot total knee arthroplasty: a systematic review.. Journal of orthopaedics. 2025. DOI: 10.1016/j.jor.2025.12.007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.