Clinical and Angiographic Outcomes of a Novel Thin Strut Poly(L-lactide) Based Bioresorbable Vascular Scaffold in Below Knee Arterial Disease: The RESOLV I First in Human Study.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Brodmann Marianne, Falah Batla, Palena Luis Mariano, Tan Kong Teng, Airoldi Flavio, Liistro Francesco, Razavi Mahmood K, Parikh Sahil A, Secemsky Eric A, Granada Juan F

Аннотация

OBJECTIVE: This first in human study evaluated the six month angiographic and one year clinical outcomes of a novel thin strut, sirolimus eluting, resorbable scaffold for symptomatic below knee peripheral arterial disease (PAD). RESOLV I is an international, prospective, multicentre, single arm study assessing the performance of the MAGNITUDE drug eluting resorbable scaffold (DRS) for the treatment of below knee lesions in patients with symptomatic PAD.

METHODS: Angiographic and duplex ultrasound evaluations were performed by independent core labs at baseline, post-DRS implantation, and at six months follow up. Binary re-stenosis (> 50% diameter stenosis) was determined via quantitative vascular angiography or duplex ultrasound when quantitative vascular angiography was unavailable. Peri-operative death, major adverse limb events, and functional status were evaluated up to one year.

RESULTS: Thirty five patients (mean age 74.5 ± 6.0 years) were enrolled: six (17%) had chronic total occlusion lesions and 25 (71%) had a baseline Rutherford-Becker classification of stage 5. The mean lesion length was 30.1 ± 12.0 mm. The binary re-stenosis rate at 6 months was 10% (3/31) (angiographic patency of 90%) and mean in segment late lumen loss was 0.75 ± 0.74 mm. Improved Rutherford class at 12 months follow up was achieved in 88% (29/33) of patients and most were asymptomatic (Rutherford-Becker class 0). No amputation or clinically driven target lesion revascularisation events were seen through 12 months.

CONCLUSION: Early results of the RESOLV I study showed that implantation of a thin strut MAGNITUDE DRS achieved low binary re-stenosis rates at six months, as well as improvement in functional status, with no clinically driven target lesion revascularisation at one year.