MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/jbhi.2025.3555255

Медицинская библиотека · IEEE journal of biomedical and health informatics · 2025

Dual Transformer Network for Predicting Joint Angles and Torques From Multi-Channel EMG Signals in the Lower Limbs.

Wang Zhuo, Chen Chunjie, Chen Hui, Zhou Yizhe, Wang Xiangyang, Wu Xinyu

СтатьяПеревод в очереди

Аннотация

Accurate estimation of lower limb joint kinematics and kinetics using wearable sensors enables biomechanical analysis beyond laboratory settings and facilitates real-time adaptation of exoskeleton assistance profiles. This study introduces a Dual Transformer Network (DTN) designed to concurrently estimate multiple joint angles and moments from multi-channel surface electromyography (sEMG) signals in the lower limbs. The performance evaluation of the predicted joint angles for the hip, knee, and ankle showed average root mean square error (RMSE) values of 1.1827, 1.4312, and 0.8113, Pearson correlation coefficients () of 0.9992, 0.9993, and 0.9991, and coefficients of determination () of 0.9847, 0.9858, and 0.9838, respectively. For the predicted joint moments, the corresponding values were RMSE of 0.0458, 0.0341, and 0.0522 Nm/kg, of 0.9978, 0.9972, and 0.9990, and of 0.9825, 0.9801, and 0.9902. Angular velocities, derived by differentiating the estimated joint angles, achieved an RMSE below 0.6530 rd/s, exceeding 0.9534, and above 0.9552. Additionally, joint power, computed as the dot product of predicted joint moments and angular velocities, resulted in RMSE below 0.3823W/kg, above 0.9771, and above 0.8925. These results demonstrate the effectiveness of the proposed network in continuously estimating lower limb kinematics and kinetics, contributing to advancements in assist-as-needed exoskeleton control strategies.

Для цитирования: Wang Zhuo, Chen Chunjie, Chen Hui, Zhou Yizhe, Wang Xiangyang, Wu Xinyu. Dual Transformer Network for Predicting Joint Angles and Torques From Multi-Channel EMG Signals in the Lower Limbs.. IEEE journal of biomedical and health informatics. 2025. DOI: 10.1109/jbhi.2025.3555255.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.