Compensating for Angiographic Underestimation With Oversized Balloon Angioplasty in Patients With Chronic Limb-Threatening Ischemia and Occluded Below-the-Knee Vessels.

Teymen Burak, Emin Öner Mehmet, Erdağ Yiğit

СтатьяПеревод в очереди

Аннотация

PURPOSE: Our study aims to determine optimal sizing of below-the-knee (BTK) artery angioplasty without intravascular ultrasound (IVUS), compensating for conventional angiography underestimation by selecting a balloon size one size larger than the 1-to-1 angiographic sizing.

MATERIALS AND

METHODS

Our study is a retrospective, single-center study. Patients were separated into 2 groups as over and angiographic reference group which the over group is larger balloon diameter selection (0.5-mm larger balloon diameter selection), and angiographic reference group is 1-to-1 balloon diameter selection by angiographic images. Primary end point was the target vessel reocclusion, whereas major and minor amputation was the secondary end point.

RESULTS

Eighty-four patients with occluded BTK lesions treated with balloon angioplasty (Opt=43, Over=41). Primary patency was 62.8% at 12 months in angiographic reference group and 82.9% in over group (p=0.039). Amputation rate at 1-year follow-up was 9.8% in angiographic reference group and 16.3% in over group (p=0.382). TLR rate is 4.9% in over group versus 20.9% in angiographic reference group (20.9%) at 1-year follow-up (p=0.029).

CONCLUSION

Our study demonstrates that oversizing the balloon diameter by one size larger in BTK artery angioplasty, guided by conventional angiography, results in a higher patency rate and a lower target lesion revascularization (TLR) rate, while amputation rate remains statistically similar between the 2 groups.Clinical ImpactOur study highlights the importance of compensating for conventional angiography's underestimation in BTK artery angioplasty by using a balloon size one size larger than the 1-to-1 angiographic sizing. Our findings demonstrate that oversizing the balloon leads to significantly higher patency rates and lower TLR rates, with no increase in amputation risk. This approach provides a practical, cost-effective solution for clinicians performing angioplasty without IVUS, allowing for better vessel treatment and outcomes in patients with chronic limb-threatening ischemia. Clinicians can implement this strategy to optimize long-term results in BTK interventions.

Для цитирования: Teymen Burak, Emin Öner Mehmet, Erdağ Yiğit. Compensating for Angiographic Underestimation With Oversized Balloon Angioplasty in Patients With Chronic Limb-Threatening Ischemia and Occluded Below-the-Knee Vessels.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2024. DOI: 10.1177/15266028241283534.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.