High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up.

Schippers Philipp, Wunderlich Felix, Afghanyar Yama, Buschmann Victoria, Klonschinski Thomas, Drees Philipp, Eckhard Lukas

СтатьяПеревод в очереди

Аннотация

PURPOSE: Despite numerous studies demonstrating promising short-term outcomes of Total Knee Arthroplasty (TKA) with Customized Individually Made (CIM) implants, there is a significant lack of data on their mid-term effectiveness. Given the increasing number of TKAs performed annually, the rising demand for CIM implants, and the associated burden of revision surgeries, understanding the mid-term performance of CIM implants is crucial. Therefore, this study aims to report on the mid-term (minimum 5 years) outcomes of TKA using a CIM implant.

METHODS

This retrospective cohort study included a consecutive series of 116 patients who received the ConforMIS® iTotal CR implant between 2015 and 2018. Inclusion criteria were end-stage knee osteoarthritis with coronal deformities below 10° and absence of ligamentous instability. Exclusion criteria included simultaneous bilateral TKA. Patients were followed up at a minimum of five years post-surgery. They completed a questionnaire reporting on satisfaction, pain levels using the Visual Analogue Scale (VAS), current weight, the Oxford Knee Score (OKS), and the Forgotten Joint Score for the knee (FJS-knee). Statistical analysis included descriptive statistics for demographic and clinical variables, and outcomes were reported as means with ranges.

RESULTS

The mean follow-up duration was 5.9 ± 0.8 years (range 5-7.4 years). 90% of patients stated they would undergo the same operation again, and 93% were either satisfied or very satisfied. The mean VAS for pain at rest was 2 ± 1.5 (range 0-6) and during exercise was 3 ± 2 (range 0-8). 58 patients (53%) managed to lose weight. The mean OKS was 41 ± 9 points (range 15-48), and the mean FJS-knee was 67 ± 23 points (range 4-100). No severe complications occurred.

CONCLUSION

CIM TKA using the ConforMIS® iTotal CR implant can achieve excellent results with 93% of patients being satisfied or very satisfied at mid-term follow-up of five years. Prospective, randomized, and patient-blinded trials comparing off-the-shelf (OTS) TKAs with CIM implants are necessary to evaluate whether these implants are superior or not.

Для цитирования: Schippers Philipp, Wunderlich Felix, Afghanyar Yama, Buschmann Victoria, Klonschinski Thomas, Drees Philipp, Eckhard Lukas. High patient satisfaction with Customized Total Knee Arthroplasty at five year follow-up.. International orthopaedics. 2024. DOI: 10.1007/s00264-024-06325-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.