MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.62948

Медицинская библиотека · Cureus · 2024

Evaluation of the External Rotation of the Femur Component in Functionally Aligned Robotic-Assisted Total Knee Arthroplasty.

Londhe Sanjay B, Rudraraju Ravi Teja, Shah Ravi Vinod, Baranwal Govindkumar, Velankar Suneet, Namjoshi Zara

СтатьяПеревод в очереди

Аннотация

Background The conventional total knee arthroplasty (TKA) for grade 4 knee arthritis lacks individualized strategies for determining femur component rotation, contributing to suboptimal clinical outcomes and heightened patient dissatisfaction. Methods One hundred consecutive active robotic-assisted TKA (RA-TKA) patients were retrospectively evaluated. The control group is the patients undergoing conventional TKA for grade 4 arthritis of the knee joint, where the femoral component is placed in a fixed 3-degree external rotation. The study aimed to explore the relationships between the posterior femoral axis of the functionally aligned TKA (FAA), the trans-epicondylar axis (TEA), and the posterior condylar axis (PCA). Specifically, it investigated whether there is a statistically significant difference in femoral component rotation between the functionally aligned TKA (FTKA) and the conventional 3-degrees of external rotation of the femoral component used in traditional TKA (C-TKA). Internal rotation is indicated by a negative value for the femur component. A student's t-test was employed to compare mean rotation values between FTKA and C-TKA, with a p-value below 0.05 considered statistically significant. Results A total of 100 patients (male: female, 11:89) were studied. The FAA was externally rotated in relation to the TEA (mean 1.451°, SD 1.023°, p-value <0.0001). As regards the PCA, the FAA was externally rotated (mean 2.36°, SD 2.221°, p-value 0.0002). These findings demonstrate a statistically significant difference in femoral component rotation between FTKA and C-TKA. Clinically, no patellofemoral complications or premature loosening were observed at one-year follow-up. Conclusion Functional alignment TKA technique resulted in external rotation of the femur component with respect to TEA and PCA. This negates the null hypothesis, indicating a statistically significant difference amongst the femur component rotation implanted according to the FTKA concept with robotic assisted technology and C-TKA.

Для цитирования: Londhe Sanjay B, Rudraraju Ravi Teja, Shah Ravi Vinod, Baranwal Govindkumar, Velankar Suneet, Namjoshi Zara. Evaluation of the External Rotation of the Femur Component in Functionally Aligned Robotic-Assisted Total Knee Arthroplasty.. Cureus. 2024. DOI: 10.7759/cureus.62948.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.