Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty-A Cohort Study with an 18-Year Follow-Up.
Аннотация
Background
Total knee arthroplasty (TKA) generates elevated metal ion concentrations, but long-term changes in the concentrations of cobalt (Co), chromium (Cr) and titanium (Ti) after primary TKA and potential subsequent immune system activation-not limited to the joint but systemically-are not known. Patients and
Methods
We conducted a cohort study on 26 patients with TKA (19 women; 16 with metal-backed and 10 with all-polyethylene tibial components) 18.3 years (min. 16.7, max. 20.5) after index TKA. A total of 69% of patients additionally underwent subsequent arthroplasty of the contralateral knee or either hip after the index surgery. Blood samples were analysed by inductively coupled plasma-mass spectrometry, and leukocytes were characterised by flow cytometry. Patients were clinically assessed using the Knee Society score and by plain radiography of the knee.
Results
The median metal ion concentrations were 0.7 (0.1-13.0) µg/L for Co, 0.9 (0.4-5.0) µg/L for Cr, and 1.0 (0.2-13.0) µg/L for Ti. There was no relevant difference in systemic metal ion concentrations between patients exposed to single and multiple arthroplasties. The absolute count and proportion of CD3+CD4+CD8+ T cells was inversely correlated with both Co (rho -0.55, p = 0.003) and Cr concentrations (rho -0.59, p = 0.001).
Conclusions
Between the first and second decades after primary TKA, in most patients, the concentrations of Co, Cr and Ti in blood samples were below the thresholds that are considered alarming. The negative correlation of Co and Cr concentrations with a subset of lymphocytes that commonly increases during immune activation is reassuring. This represents a worst-case scenario, underscoring that the investigated metal ions remain within reasonable ranges, even after additional hardware exposure.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.