The arthroscopic Latarjet procedure with a posterior guided system and suture-button fixation enables more precise bone block positioning in the axial plane versus anterior screws fixation.

Gaujac Nicolas, Bouché Pierre-Alban, Belas Maxime, Bonnevialle Nicolas, Charousset Christophe

СтатьяПеревод в очереди

Аннотация

PURPOSE: Adequate position of the bone block during arthroscopic Latarjet procedure is critical for an optimal functional outcome. However, this procedure is complex with a long learning curve. Our aim was to compare the bone block position between a dedicated glenoid posterior instrumentation and suture button fixation versus an anterior screw fixation, on a postoperative computed tomography (CT) scan.

METHOD: Seventy-nine consecutive patients operated on for an anterior shoulder instability were included in this retrospective study. The same surgeon performed arthroscopically the Latarjet procedure either with an anterior drilling and screw fixation (Group A), or with a specific posterior glenoid guide pin, a posterior drilling, and a suture cortical button fixation (Group B). Evaluations were made by two independent observers. The position was evaluated by CT scan in the axial and sagittal planes. Learning curves with operative time, complications and clinical outcomes were assessed at a minimum of 2 years of follow-up.

RESULTS

Thirty-five patients were included in Group A and 44 in Group B. In Group A, 27 bone blocks were flush (87.1%) and 38 in Group B (92.7%) (p < 0.01). In Group A, 72% of the bone block height was below the equator and 76%, in Group B (ns). The mean operating time was 123 ± 32.5 min in Group A and 95 ± 34.1 min in Group B (p < 0.0001). At the final follow-up, the mean aggregate Rowe score was respectively 94.6 ± 10.4 and 93.1 ± 9.8 points in Groups A and B. The mean aggregate Walch-Duplay score was respectively 94.2 ± 11.6 and 93.4 ± 10.6 points in Groups A and B. There were 11 complications (31.4%) in Group A and five complications (11.3%) in Group B (ns).

CONCLUSION

The arthroscopic Latarjet procedure with a posterior drilling guided system and suture-button fixation allows more precise positioning in the axial plane than with anterior drilling and screw fixation. This posterior-guided procedure could reduce intraoperative and short-term complications.

LEVEL OF EVIDENCE: Level IV.

Для цитирования: Gaujac Nicolas, Bouché Pierre-Alban, Belas Maxime, Bonnevialle Nicolas, Charousset Christophe. The arthroscopic Latarjet procedure with a posterior guided system and suture-button fixation enables more precise bone block positioning in the axial plane versus anterior screws fixation.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2024. DOI: 10.1002/ksa.12063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.