MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.avsg.2022.04.011

Медицинская библиотека · Annals of vascular surgery · 2022

Contemporary Results with the Biosynthetic Glutaraldehyde Denatured Ovine Collagen Graft (Omniflow II) in Lower Extremity Arterial Revascularization in a Septic Context.

Caradu Caroline, Brunet Céline, Spampinato Benedetta, Stenson Katherine, Ducasse Eric, Pugès Mathilde, Berard Xavier

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Peripheral vascular graft infections are poorly-evaluated, despite high mortality and amputation rates. The vascular substitute of choice remains controversial when veins are unavailable. This study aims to evaluate the results of a biosynthetic collagen graft (Omniflow II®) in an infected field when autologous veins are unavailable.

METHODS

This retrospective, multicentric study included all consecutive patients in whom an Omniflow II graft was used for infra-inguinal revascularization in a septic context from January 2015 to January 2020. The primary end-point was freedom from major amputation; secondary end-points were 30-day mortality, survival, patency, and freedom from reinfection estimated using the Kaplan-Meier method.

RESULTS

Twenty-nine patients (27 men, median age of 69 years interquartile range IQR:60; 76) were included. Fever was present in 58.6%, a septic rupture in 17.9%, a pseudo-aneurysm in 25.0%. The 30-day mortality rate was 3.4%. Median follow-up reached 49 months. At 1 and 3 years, estimated freedom from major amputation was 88.4% and 83.9%, survival: 96%, primary patency: 74.6% and 65.8%, and reinfection free-survival: 85.6%. There were 7 occlusions (1 iliofemoral, 1 below-knee, and 5 above-knee bypasses), 3 explantations for persistent sepsis, 4 reinfections (all within 6 months which led to 1 death and 3 out of 4 major amputations). The risk of major amputation increased with bypass reinfection (P = 0.004), occlusion (P = 0.005), and polymicrobial infection (P = 0.05).

CONCLUSIONS

In a septic context, the Omniflow II graft shows acceptable freedom from major amputation and reinfection. This usage remains outside the instructions of use, it is, therefore, is essential to pursue longer-term studies in larger cohorts.

Для цитирования: Caradu Caroline, Brunet Céline, Spampinato Benedetta, Stenson Katherine, Ducasse Eric, Pugès Mathilde, Berard Xavier. Contemporary Results with the Biosynthetic Glutaraldehyde Denatured Ovine Collagen Graft (Omniflow II) in Lower Extremity Arterial Revascularization in a Septic Context.. Annals of vascular surgery. 2022. DOI: 10.1016/j.avsg.2022.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.