Медицинская библиотека · Cardiovascular and interventional radiology · 2018

CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol.

Horehledova Barbora, Mihl Casper, Milanese Gianluca, Brans Rutger, Eijsvoogel Nienke G, Hendriks Babs M F, Wildberger Joachim E, Das Marco

СтатьяПеревод в очереди

Аннотация

PURPOSE: The ALARA principle is not only relevant for effective dose (ED) reduction, but also applicable for contrast media (CM) management. Therefore, the aim was to evaluate the feasibility of an ultra-low CM protocol in the assessment of peripheral artery disease (PAD).

MATERIALS AND

METHODS

Fifty PAD patients were scanned on third-generation dual-source computed tomography, from diaphragm to the forefoot, as follows: tube voltage: 70 kV, reference effective tube current: 90 mAs, collimation: 192 × 2 × 0.6 mm, with individualized acquisition timing. The protocol ED (mSv) was quantified with dedicated software. CM protocol consisted of 15 ml test bolus and 30 ml main bolus (300 mgI/ml) injected at 5 ml/s, followed by a 40 ml saline chaser at the same flow rate. Aorto-popliteal bolus transit time was used to calculate the overall acquisition time and delay. Objective (hounsfield units-HU; contrast-to-noise ratio-CNR) and subjective image quality (four-point Likert score) were assessed at different anatomical regions from the aorta down to the forefoot.

RESULTS

Mean attenuation values were exceeding 250 HU from aorta down to the anterior tibial artery with CNR < 13. However, decline in attenuation was observed in more distal region with mean values of 165 and 199 HU, in left and right dorsalis pedis artery, respectively. Mode subjective image quality from the level of aorta down to the popliteal segment was excellent; below the knee mode score was good. The mean ED per protocol was 1.1 ± 0.5 mSv.

CONCLUSION

Use of an ultra-low CM volume protocol at 70 kV is feasible in the evaluation of PAD, resulting in good to excellent image quality with mean ED of 1.1 ± 0.5 mSv.

LEVEL OF EVIDENCE: Level 3, Local non-random sample.

Для цитирования: Horehledova Barbora, Mihl Casper, Milanese Gianluca, Brans Rutger, Eijsvoogel Nienke G, Hendriks Babs M F, Wildberger Joachim E, Das Marco. CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol.. Cardiovascular and interventional radiology. 2018. DOI: 10.1007/s00270-018-1979-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.