MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apmr.2016.12.001

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2016

Microcirculatory Assessment of Arterial Below-Knee Stumps: Near-Infrared Spectroscopy Versus Transcutaneous Oxygen Tension-A Preliminary Study in Prosthesis Users.

Laroche Davy, Barnay José-Luis, Tourlonias Bastien, Orta Cyril, Obert Christine, Casillas Jean-Marie

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To examine metrologic properties of near-infrared spectroscopy (NIRS) versus transcutaneous oxygen tension (TcPO2) for microcirculatory assessment of vascular transtibial stumps at the stabilized period of prosthesis fitting, as a preliminary step before exploring its ability to predict stump healing, considering the previously identified limits of TcPO2 (borderline area between 15 and 35mmHg).

DESIGN

Prospective single-center observational study.

SETTING

University-based rehabilitation center.

PARTICIPANTS

Individuals with unilateral transtibial amputation for peripheral artery disease, at the definitive stage of prosthesis fitting, able to perform a 2-minute walk test (N=30).

INTERVENTIONS: Not applicable.

MAIN OUTCOME MEASURES: Test-retest, with the stump being evaluated in supine and inclined positions, first by NIRS (tissue saturation index [TSI], oxyhemoglobin, deoxyhemoglobin, and total hemoglobin) and second by TcPO2. Subjects carried out a 2-minute walk test and visual analog scales (wound healing and pain).

RESULTS

Feasibility and tolerance of NIRS were satisfactory. The reliability of NIRS and TcPO2 values was good (intraclass correlation coefficient >0.7; P<.05). No significant relation was found between NIRS and TcPO2. No responsiveness (inclined vs supine) was reported (P>.05). A significant relation between TSI and the 2-minute walk test (r>.49, P<.05) was found.

CONCLUSIONS

NIRS is painless, complication-free, and feasible, with good reliability. NIRS evaluates others domain than TcPO2 that are more linked to metabolic adaptation. Its capacity to predict stump healing and tolerance to early prosthesis fitting is therefore interesting to estimate in future studies.

Для цитирования: Laroche Davy, Barnay José-Luis, Tourlonias Bastien, Orta Cyril, Obert Christine, Casillas Jean-Marie. Microcirculatory Assessment of Arterial Below-Knee Stumps: Near-Infrared Spectroscopy Versus Transcutaneous Oxygen Tension-A Preliminary Study in Prosthesis Users.. Archives of physical medicine and rehabilitation. 2016. DOI: 10.1016/j.apmr.2016.12.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.