The Journal of cardiovascular surgery · 2016
Intra-arterial injection of iloprost reduces the risk of early recoil after balloon angioplasty of below-the-knee vessels in patients with critical limb ischemia.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Troisi Nicola, Farina Alberto, Chisci Emiliano, Ercolini Leonardo, Frosini Pierfrancesco, Pigozzi Clara, Guidotti Azzurra, Michelagnoli Stefano
Аннотация
BACKGROUND: Previous studies demonstrated that early recoil is frequently observed in patients undergoing balloon angioplasty. The aim of this study was to evaluate the impact of intra-arterial administration of iloprost (Endoprost®, Italfarmaco S.p.A., Milan, Italy) on early elastic recoil after balloon angioplasty of below-the-knee (BTK) vessels in patients with critical limb ischemia (CLI).
METHODS: Between January 2015 and December 2015 32 patients with CLI underwent balloon angioplasty of at least one BTK vessel followed by intra-arterial administration of iloprost. Early elastic recoil was defined as residual lumen compromise >10%. Early elastic recoil was determined on the basis of minimal lumen diameter (MLD) measurements at baseline (MLDbaseline), immediately after BTK balloon angioplasty (MLDpostdilation), and 15 minutes thereafter (MLD15min).
RESULTS: Patients were predominantly female (18/32, 56.2%) with a mean age of 79.6 years (range 68-87). Most of the patients were diabetics (25/32, 78.1%). An occlusion was present in 24 cases (75%). Mean BTK lesion length was 144.1 mm (range 22-320). Mean MLD measurements were 0.1 mm (range 0-0.5; MLDbaseline), 2.5 mm (range 1.9-3; MLDpostdilation), and 1.9 mm (range 0.7-3; MLD15min). Early elastic recoil was recorded in 14 patients (43.8%). The mean percentage of elastic recoil after 15 minutes was 21.4%.
CONCLUSIONS: In our experience intra-arterial administration of iloprost reduces the risk of early elastic recoil after balloon angioplasty of BTK vessels in patients with CLI. Further analyses with larger population studies and randomized trials are needed to validate this therapeutic option.
METHODS: Between January 2015 and December 2015 32 patients with CLI underwent balloon angioplasty of at least one BTK vessel followed by intra-arterial administration of iloprost. Early elastic recoil was defined as residual lumen compromise >10%. Early elastic recoil was determined on the basis of minimal lumen diameter (MLD) measurements at baseline (MLDbaseline), immediately after BTK balloon angioplasty (MLDpostdilation), and 15 minutes thereafter (MLD15min).
RESULTS: Patients were predominantly female (18/32, 56.2%) with a mean age of 79.6 years (range 68-87). Most of the patients were diabetics (25/32, 78.1%). An occlusion was present in 24 cases (75%). Mean BTK lesion length was 144.1 mm (range 22-320). Mean MLD measurements were 0.1 mm (range 0-0.5; MLDbaseline), 2.5 mm (range 1.9-3; MLDpostdilation), and 1.9 mm (range 0.7-3; MLD15min). Early elastic recoil was recorded in 14 patients (43.8%). The mean percentage of elastic recoil after 15 minutes was 21.4%.
CONCLUSIONS: In our experience intra-arterial administration of iloprost reduces the risk of early elastic recoil after balloon angioplasty of BTK vessels in patients with CLI. Further analyses with larger population studies and randomized trials are needed to validate this therapeutic option.