High-pitch carbon dioxide contrasted CT angiography: pilot study.

Penzkofer Tobias, Slebocki Karin, Grommes Jochen, Bruners Philipp, Isfort Peter, Schmitz-Rode Thomas, Langer Stephan, Kuhl Christiane K, Mahnken Andreas H

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study was designed to evaluate CO2 computed tomography angiography (CO2-CTA) of the iliac and lower limb arteries in patients with contraindications for iodinated contrast agent (ICA).

METHODS

Five patients with contraindications for ICA were examined using CO2-fluoroscopic enhanced angiography (CO2-FLA) and CO2-CTA using a high-pitch examination protocol. Objective (vessel diameter) and subjective (visual score) image quality parameters were evaluated. Pathological findings in both modalities were compared.

RESULTS

CO2-CTA was feasible in all patients without adverse side effects, except for CO2 injection-associated pain. Objective vessel analysis revealed no significant difference in diameters as determined by CO2-CTA and CO2-FLA (0.44 ± 0.4 and 0.46 ± 0.41 mm, p = 0.93). CO2-CTA had on average a higher image-quality score (2.6 ± 1.0 vs. 2.3 ± 1.0, p = 0.009). While for pelvic and upper leg CO2-CTA advantageous (3.1 ± 0.74 vs. 2.7 ± 0.9, p = 0.0014) at good quality scores, for calf vessels no significant improvement was visible (1.9 ± 1.0 vs. 1.7 ± 0.9, p = 0.49) and scores were poorer.

CONCLUSIONS

CO2-CTA with high-pitch CT was feasible in a limited number of patients. Image-quality scores were on average higher for CO2-CTA than for CO2-FLA, while limited imaging quality in the vessels below the knee needs further work on the CT protocol. An added value of cross-sectional imaging was apparent but needs further quantification.

Для цитирования: Penzkofer Tobias, Slebocki Karin, Grommes Jochen, Bruners Philipp, Isfort Peter, Schmitz-Rode Thomas, Langer Stephan, Kuhl Christiane K, Mahnken Andreas H. High-pitch carbon dioxide contrasted CT angiography: pilot study.. Cardiovascular and interventional radiology. 2014. DOI: 10.1007/s00270-013-0834-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.