La Radiologia medica · 2009
Comparison between 64-row CT angiography and digital subtraction angiography in the study of lower extremities: personal experience.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cernic S, Pozzi Mucelli F, Pellegrin A, Pizzolato R, Cova M A
Аннотация
PURPOSE: This study was undertaken to evaluate the potential of 64-row multislice computed tomography (CT) versus digital subtraction angiography (DSA) in detecting significant lesions of lower-extremity inflow and runoff arteries.
MATERIALS AND METHODS: Fifty-three patients underwent 64-row multislice CT and DSA over a mean of 36 days. The vascular tree was divided into 33 segments. Three readers independently reviewed the axial CT scans and multiplanar oblique and two- and three-dimensional reconstructions (maximum intensity projection and volume rendering) images to assess degree of stenosis according to four categories: 1 (0%-49% stenosis); 2 (50%-99% stenosis); 3 (occluded); 4 (not evaluable). In all cases, DSA was performed by arterial catheterisation.
RESULTS: In 53 patients, 1,440 segments were evaluated (infrarenal aorta and 16 arterial segments for each leg; 42 bilateral studies, 11 unilateral studies). Compared with DSA, CT angiography yielded 97.2% sensitivity, 97% specificity, 92.5% positive predictive value, 98.9% negative predictive value, 97.1% diagnostic accuracy and 95.4% concordance on the degree of stenosis.
CONCLUSIONS: Sixty-four-row multislice CT proved to be helpful in detecting haemodynamically significant lesions in peripheral arterial occlusive disease and improved the results obtained with 4- and 16-slice multidetector CT. In addition, owing to the high spatial resolution and rigorous technique, no variations in the data obtained below the knee were detected, overcoming a limitation of earlier generations of CT scanners.
MATERIALS AND METHODS: Fifty-three patients underwent 64-row multislice CT and DSA over a mean of 36 days. The vascular tree was divided into 33 segments. Three readers independently reviewed the axial CT scans and multiplanar oblique and two- and three-dimensional reconstructions (maximum intensity projection and volume rendering) images to assess degree of stenosis according to four categories: 1 (0%-49% stenosis); 2 (50%-99% stenosis); 3 (occluded); 4 (not evaluable). In all cases, DSA was performed by arterial catheterisation.
RESULTS: In 53 patients, 1,440 segments were evaluated (infrarenal aorta and 16 arterial segments for each leg; 42 bilateral studies, 11 unilateral studies). Compared with DSA, CT angiography yielded 97.2% sensitivity, 97% specificity, 92.5% positive predictive value, 98.9% negative predictive value, 97.1% diagnostic accuracy and 95.4% concordance on the degree of stenosis.
CONCLUSIONS: Sixty-four-row multislice CT proved to be helpful in detecting haemodynamically significant lesions in peripheral arterial occlusive disease and improved the results obtained with 4- and 16-slice multidetector CT. In addition, owing to the high spatial resolution and rigorous technique, no variations in the data obtained below the knee were detected, overcoming a limitation of earlier generations of CT scanners.
Предметные рубрики MeSH
AgedAged, 80 and overAngiographyAngiography, Digital SubtractionFemaleHumansImage Processing, Computer-AssistedKneeLegLower ExtremityMaleMiddle AgedPeripheral Vascular DiseasesPredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSensitivity and SpecificityThighTomography, X-Ray Computed