Are room temperature and thermal neutral synonymous terms? An investigation of common therapeutic modality control variables.

Hawkins Jeremy R, Knight Kenneth L, Long Blaine C

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

CONTEXT: Therapeutic modality control variables are thought to be thermal neutral, a term sometimes used interchangeably with room temperature. We question this common assumption.

OBJECTIVE

To determine thermal neutrality of common therapeutic modality control variables.

DESIGN

We performed 5 laboratory experiments, including (1) water temperature over 3 weeks in 3 different containers (glass, plastic, and polystyrene); (2) water temperature and volume of 4 beakers (2 insulated, 2 uninsulated) over 4 weeks, with 1 beaker of each type covered by polyethylene; and skin interface temperature of (3) a dry, nonheated hydrocollator pack held against the chest, (4) kitty litter applied to the knee, and (5) room-temperature ultrasound gel to the forearm.

SETTING

Therapeutic modalities laboratory.

PATIENTS OR OTHER

PARTICIPANTS

College student volunteers were subjects in experiments 3, 4, and 5.

MAIN OUTCOME MEASURE(S): We measured temperature and volume change. Data were evaluated using descriptive and interferential statistics.

RESULTS

Water temperature plateaued significantly below room temperature. Temperatures significantly increased in all but the open, insulated container. Open containers plateaued at approximately 2 degrees C below room temperature and lost significant amounts of water; closed containers plateaued at room temperature with negligible water loss. In experiments 3 through 5, skin temperatures rose significantly during hydrocollator pack, kitty litter, and ultrasound gel application.

CONCLUSIONS

Room-temperature water baths, dry hydrocollator packs, kitty litter, and ultrasound gel were not thermally neutral. Room temperature should not be used synonymously with thermal neutral. Care must be taken to ensure that control variables truly are controlled.

Для цитирования: Hawkins Jeremy R, Knight Kenneth L, Long Blaine C. Are room temperature and thermal neutral synonymous terms? An investigation of common therapeutic modality control variables.. Journal of athletic training. 2007.