MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/art.21803

Медицинская библиотека · Arthritis and rheumatism · 2006

Hyaluronan molecular reflection by synovial lining is concentration dependent and reduced in dilute effusions in a rabbit model.

Sabaratnam S, Mason R M, Levick J R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Hyaluronan (HA) has a major role in regulating synovial fluid volume. This role depends on the synovium functioning as an ultrafilter that reflects HA during trans-synovial fluid drainage. Reflection boosts the HA concentration on the membrane surface, leading to osmotic retention of synovial fluid ("buffering"). In arthritic effusions, however, HA concentration and osmotic buffering are greatly reduced. We tested the hypothesis that reflection is reduced (escape increased) when the HA concentration falls below the molecular entanglement concentration (C*).

METHODS

HA at 0.2 mg/ml (<C*) or 1.5 mg/ml (>C*) was infused continuously into rabbit knee joints to set up a steady trans-synovial filtration. Joint-derived lymph was sampled over 3 hours, and subsynovial fluid was sampled at the end of the 3-hour period. HA was quantified by high-performance liquid chromatography to evaluate the reflected fraction. C* was determined by viscometry.

RESULTS

Viscometry showed that 0.2 mg/ml HA was below C* and 1.5 mg/ml was above it. At 0.2 mg/ml, the mean +/- SEM HA reflected fraction was 0.66 +/- 0.04 (n = 7). At 1.5 mg/ml the reflection increased to 0.88 +/- 0.04 (n = 5) (P < 0.005). HA permeation increased almost 3-fold, from 12% to 34%, at the lower concentration.

CONCLUSION

Chain-chain interaction at >C* increases effective molecular domain size and hence HA reflection, promoting effective conservation of synovial fluid in normal joints. HA can fall below C* (approximately 1 mg/ml) in arthritic effusions, promoting loss of HA. The attendant failure of outflow buffering facilitates fluid escape and periarticular edema.

Для цитирования: Sabaratnam S, Mason R M, Levick J R. Hyaluronan molecular reflection by synovial lining is concentration dependent and reduced in dilute effusions in a rabbit model.. Arthritis and rheumatism. 2006. DOI: 10.1002/art.21803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.