MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/jars.2002.29877

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2002

The split-line pattern of the distal femur: A consideration in the orientation of autologous cartilage grafts.

Below Steven, Arnoczky Steven P, Dodds Julie, Kooima Cynthia, Walter Norman

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To identify the surface collagen orientations of the distal femur and create a generic cartilage split-line map that could be used as a reference guide for the proper alignment of autogenous cartilage transplants.

TYPE OF STUDY: Anatomic, cadaveric study.

METHODS

Eight fresh cadaveric knee joints were used to determine the collagen fiber orientation of the superficial layer of the articular cartilage of the distal femur. A split-line technique was used, in which a dissecting needle dipped in India ink was inserted into the cartilage. The resulting split between collagen fibers identified the preferential orientation of the collagen fibers at each needle insertion point.

RESULTS

The results of the study show that a precise and consistent orientation of collagen fibers exists in areas that are known to experience significant joint load.

CONCLUSIONS

Because the orientation of these split lines is thought to reflect the direction of tensile forces normally seen by the articular cartilage at a specific area, we hypothesize that proper orientation of autogenous cartilage plugs (with respect to split-line direction) may maximize resistance to these tensile forces and thus optimize the long-term health of these cartilage plugs.

Для цитирования: Below Steven, Arnoczky Steven P, Dodds Julie, Kooima Cynthia, Walter Norman. The split-line pattern of the distal femur: A consideration in the orientation of autologous cartilage grafts.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2002. DOI: 10.1053/jars.2002.29877.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.