MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Annales de chirurgie · 1999

[Mechanical evaluation of a ligament fixation system for ACL reconstruction at the tibia in a canine cadaver model].

Leduc S, Yahia L, Boudreault F, Fernandes J C, Duval N

СтатьяПеревод в очереди

Аннотация

OBJECT: Excellent fixation of an artificial ligament in bone is mandatory for initial stability. ACL reconstruction with the LARS artificial ligament may fail if anchorage to bone is inadequate. The weak metaphyseal bone of the proximal tibia is prone to inadequate fixation. This study evaluates the initial mechanical stability of two techniques with an interference screw on the tibial side of an ACL reconstruction with the LARS ligament.

METHODS

Six left tibias were obtained from 1 to 3 year old mongrel dog weighing 20 to 26 kg. ACL straight line reconstruction according to the technique described by J.P. Laboureau was performed with a 4.5 mm drill. Two tunnels were created in the tibia, one oblique and one transverse, the latter 2 cm below the former. Reconstruction was done with a 30-fiber LARS ligament and a 5.2 mm x 15 mm conical titanium cannulated interference screw. Group I had an interference screw in the oblique tunnel and group II had an interference screw in the transverse tunnel. Pull-out tests were performed parallel to the oblique tunnel on an Instron 8521 machine at a speed of 5 mm per minute until failure. The oblique tunnel was tested first then the transverse tunnel.

RESULTS

Group I (n = 6): sliding value = 238 +/- 115 N. Group II (n = 6): sliding value = 998 +/- 148 N. This is statistically significant (p < 0.001, student t-test).

CONCLUSION

One interference screw in a transverse tibial tunnel for ACL reconstruction with the LARS ligament is 4 times more resistant on loading and impact than an oblique screw.

Для цитирования: Leduc S, Yahia L, Boudreault F, Fernandes J C, Duval N. [Mechanical evaluation of a ligament fixation system for ACL reconstruction at the tibia in a canine cadaver model].. Annales de chirurgie. 1999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.