MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0357025

Медицинская библиотека · PloS one · 2026

Predicting the right! Validation of right heart failure predictive risk models after primary durable ventricular assist device implantation.

Sales Marjolijn Carolien, Zayat Rachad, Hatam Nima, Berg Thomas, Tewarie Lachmandath, Moza Ajay, Ramnath Natasja Wanita Monisha

СтатьяНаблюдательное исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Perioperative right heart failure remains a severe complication after durable left ventricular assist device implantation. Accurate preoperative risk assessment is crucial to identify patients requiring advanced medical or mechanical biventricular support. Existing predictive risk models show limited comparability and lack consistent external validation. We aimed to validate commonly used right heart failure risk models using a standardized definition and, as a secondary exploratory analysis, to evaluate a parsimonious Firth-penalized model in our cohort.

METHODS

We performed a single-center, retrospective observational study of 105 patients undergoing durable left ventricular assist device implantation from April 2015 to February 2023. Right heart failure was defined according to the Interagency Registry for Mechanically Assisted Circulatory Support definition. Preoperative EUROMACS, Michigan, CRITT, BiVAD, Utah, and a modified Utah score were calculated. The postoperative EUROMACS score, which includes cardiopulmonary bypass time, was analyzed separately as an early perioperative risk marker. Discrimination was assessed using receiver-operating characteristic analysis. The exploratory five-variable Firth model was internally validated by bootstrap optimism correction and calibration analysis.

RESULTS

Moderate-severe right heart failure occurred in 21 patients (20.4%). Among established scores, AUC values ranged from 0.394 (Utah) to 0.729 (postoperative EUROMACS). The exploratory five-variable Firth model, including INTERMACS profile, total bilirubin, aspartate aminotransferase, diastolic pulmonary artery pressure, and pulmonary vascular resistance, showed an apparent AUC of 0.854. After 2,000 bootstrap resamples, the optimism-corrected AUC was 0.773, with an optimism-corrected Brier score of 0.149 and calibration slope of 0.586, indicating relevant optimism and potential overfitting.

CONCLUSIONS

Established right heart failure risk scores showed limited-to-moderate discrimination in this cohort. Postoperative EUROMACS achieved the highest AUC but should not be interpreted as a purely preoperative prediction tool. The exploratory Firth model identified a potentially informative combination of clinical status, hepatic laboratory markers, and pulmonary hemodynamics, but remains hypothesis-generating and requires external validation before clinical implementation.

Для цитирования: Sales Marjolijn Carolien, Zayat Rachad, Hatam Nima, Berg Thomas, Tewarie Lachmandath, Moza Ajay, Ramnath Natasja Wanita Monisha. Predicting the right! Validation of right heart failure predictive risk models after primary durable ventricular assist device implantation.. PloS one. 2026. DOI: 10.1371/journal.pone.0357025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.