MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/11866565_68

Медицинская библиотека · Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention · 2006

Visual servoing for intraoperative positioning and repositioning of mobile C-arms.

Navab Nassir, Wiesner Stefan, Benhimane Selim, Euler Ekkehard, Heining Sandro Michael

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

The problem of positioning mobile C-arms, e.g. for down the beam techniques, as well as repositioning during surgical procedures currently requires time, skill and additional radiation. This paper uses a Camera-Augmented Mobile C-arm (CAMC) to speed up the procedure, simplify its execution and reduce the necessary radiation. For positioning the C-arm in down-the-beam position, the pre-operative diagnostic CT is used for defining the axis. Additional CT visible markers on patient's skin allow the CAMC's optical camera to compute the C-arm's pose and its required displacement for positioning. In the absence of electronically controlled mobile C-arms, the system provides step-by-step guidance to surgical staff until the final position is achieved. At this point, the surgeon can acquire an X-ray to ensure the correct positioning. In the case of intra-operative repositioning, no pre-operative CT is required. X-ray/Optical markers allow the visual servoing algorithm to guide the surgical staff in C-arm repositioning using CAMC's optical camera. This work paves the path for many possible applications of visual servoing in C-arm positioning and in surgical navigation. Experiments on phantom and a cadaver study demonstrate the advantages of the new methods.

Для цитирования: Navab Nassir, Wiesner Stefan, Benhimane Selim, Euler Ekkehard, Heining Sandro Michael. Visual servoing for intraoperative positioning and repositioning of mobile C-arms.. Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention. 2006. DOI: 10.1007/11866565_68.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.