The international journal of medical robotics + computer assisted surgery : MRCAS · 2026
Adaptive Grid Search Method Using Dynamic Step-Size Adjustment for Robot-Tissue Interaction Force Estimation.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhu Yinzhi, Li Hongbing
Аннотация
BACKGROUND: Reliable force perception is critical in robot-assisted minimally invasive surgery. However, constraints in end-effector size and complexity of the surgical environment hamper the integration of force sensors for direct feedback.
METHODS: In this study, an adaptive grid search algorithm with dynamic step-size adjustment is proposed to optimise the Hunt-Crossley (HC) model parameters for precise force estimation in robotic applications. The method continuously adjusts the step size based on real-time estimation error, thereby enabling efficient investigation of the parameter space and refined optimisation near the optimal solution.
RESULTS: Experimental results show that the proposed method improves force estimation accuracy, with a reduction in Maximum Error (ME) of at least 25%, and reductions in Root Mean Square Error (RMSE) and Average Error (AE) of at least 30% compared to conventional fixed-step approaches.
CONCLUSIONS: These improvements enhance operational safety and also achieve the balance between computational efficiency and perception accuracy.
METHODS: In this study, an adaptive grid search algorithm with dynamic step-size adjustment is proposed to optimise the Hunt-Crossley (HC) model parameters for precise force estimation in robotic applications. The method continuously adjusts the step size based on real-time estimation error, thereby enabling efficient investigation of the parameter space and refined optimisation near the optimal solution.
RESULTS: Experimental results show that the proposed method improves force estimation accuracy, with a reduction in Maximum Error (ME) of at least 25%, and reductions in Root Mean Square Error (RMSE) and Average Error (AE) of at least 30% compared to conventional fixed-step approaches.
CONCLUSIONS: These improvements enhance operational safety and also achieve the balance between computational efficiency and perception accuracy.