DOI 10.1016/j.mri.2015.12.012

Медицинская библиотека · Magnetic resonance imaging · 2015

Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7T.

van der Velden Tijl A, Schmitz Alexander M Th, Gilhuijs Kenneth G A, Veldhuis Wouter B, Luijten Peter R, Boer Vincent O, Klomp Dennis W J

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To compare water selective excitation (WSE) and Dixon fat suppression in the context of high-resolution dynamic contrast enhanced MRI of the breast at 7T.

METHODS

Ten healthy volunteers and one patient with a malignant breast lesion were scanned at 7T. The MRI protocol contained 3D T1-weighted gradient echo images obtained with both WSE fat suppression, multi echo Dixon fat suppression, and without fat suppression. Images were acquired at a (0.8mm)(3) or (0.7mm)(3) isotropic resolution with equal field of view and optimized such to obtain a maximal SNR. Image quality was scored qualitatively on overall image quality, sharpness of anatomical details, presence of artifacts, inhomogeneous fat suppression and the presence of water-fat shift. A quantitative scoring was obtained from the signal to noise ratio and contrast to noise ratio.

RESULTS

WSE scored significantly better in terms of overall image quality and the absence of artifacts. No significant difference in contrast to noise ratio was found between the two fat suppression methods.

CONCLUSION

When maximizing temporal and spatial resolution of high resolution DCE MRI of the breast, water selective excitation provides better image quality than multi echo Dixon at 7T.

Для цитирования: van der Velden Tijl A, Schmitz Alexander M Th, Gilhuijs Kenneth G A, Veldhuis Wouter B, Luijten Peter R, Boer Vincent O, Klomp Dennis W J. Fat suppression techniques for obtaining high resolution dynamic contrast enhanced bilateral breast MR images at 7T.. Magnetic resonance imaging. 2015. DOI: 10.1016/j.mri.2015.12.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.