MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2011.03.001

Медицинская библиотека · European journal of radiology · 2011

A systematic comparison of two pulse sequences for edema assessment in MR-mammography.

Baltzer P A T, Dietzel M, Gajda, Camara O, Kaiser W A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

Perifocal edema, defined as high T2w signal intensity around an enhancing lesion has been described as a specific feature of malignancy. In clinical MR-mammography (MRM), both fatsat and non-fatsat T2w sequences are available. However, there is no consensus on which technique should be used for edema assessment. Consequently, this investigation was performed to compare two commonly used pulse sequences for edema assessment in MRM.

MATERIALS AND

METHODS

321 consecutive patients from a 22 month period were included in this investigation. Further selection criteria were histopathological verification of enhancing lesions and absence of presurgical chemotherapy or biopsy, resulting in 108 malignant and 107 benign lesions. All underwent MRM according to international guidelines including a non-fatsat T2w-TSE sequence (TR/TE: 8900/207 ms) and a short tau inversion recovery fatsat sequence (STIR, TR/TE: 8420/70 ms). All images were acquired in the same orientation (axial) and slice thickness. Two experienced radiologists in consensus rated presence of perifocal edema according to an ordinal scale: 0 = not present, 1 = little, 2 = intermediate, and 3 = distinct. Data analysis was performed using crosstabs and Visual Grading Characteristics (VGC) analysis.

RESULTS

Overall sensitivity/specificity was calculated with 53.7%/94.4% (T2w-TSE) and 52.8%/95.3% (STIR). VGC revealed an area under the VGC curve of 0.502 (standard error 0.026), P = 0.814.

CONCLUSION

Perifocal edema is a specific feature of malignancy with moderate sensitivity. VGC analysis did not reveal significant differences between both pulse sequences analysed. Consequently, both T2w-TSE and STIR images are suitable for assessment of perifocal edema.

Для цитирования: Baltzer P A T, Dietzel M, Gajda, Camara O, Kaiser W A. A systematic comparison of two pulse sequences for edema assessment in MR-mammography.. European journal of radiology. 2011. DOI: 10.1016/j.ejrad.2011.03.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.