DOI 10.1016/j.acra.2009.07.010

Медицинская библиотека · Academic radiology · 2009

Conspicuity of microcalcifications on digital screening mammograms using varying degrees of monitor zooming.

Haygood Tamara Miner, Arribas Elsa, Brennan Patrick C, Atkinson E Neely, Herndon Mark, Dieber Joseph, Geiser William, Santiago Lumarie, Mills Chadwick M, Davis Paul, Adrada Beatriz, Carkaci Selin, Stephens Tanya W, Whitman Gary J

СтатьяПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

American College of Radiology guidelines suggest that digital screening mammographic images should be viewed at the full resolution at which they were acquired. This slows interpretation speed. The aim of this study was to examine the effect of various levels of zooming on the detection and conspicuity of microcalcifications.

MATERIALS AND

METHODS

Six radiologists viewed 40 mammographic images five times in different random orders using five different levels of zooming: full resolution (100%) and 30%, 61%, 88%, and 126% of that size. Thirty-three images contained microcalcifications varying in subtlety, all associated with breast cancer. The clusters were circled. Seven images contained no malignant calcifications but also had randomly placed circles. The radiologists graded the presence or absence and visual conspicuity of any calcifications compared to calcifications in a reference image. They also counted the microcalcifications.

RESULTS

The radiologists saw the microcalcifications in 94% of the images at 30% size and in either 99% or 100% of the other tested levels of zooming. Conspicuity ratings were worst for the 30% size and fairly similar for the others. Using the 30% size, two radiologists failed to see the microcalcifications on either the craniocaudal or mediolateral oblique view taken from one patient. Interobserver agreement regarding the number of calcifications was lowest for the 30% images and second lowest for the 100% images.

CONCLUSIONS

Images at 30% size should not be relied on alone for systematic scanning for microcalcifications. The other four levels of magnification all performed well enough to warrant further testing.

Для цитирования: Haygood Tamara Miner, Arribas Elsa, Brennan Patrick C, Atkinson E Neely, Herndon Mark, Dieber Joseph, Geiser William, Santiago Lumarie, Mills Chadwick M, Davis Paul, Adrada Beatriz, Carkaci Selin, Stephens Tanya W, Whitman Gary J. Conspicuity of microcalcifications on digital screening mammograms using varying degrees of monitor zooming.. Academic radiology. 2009. DOI: 10.1016/j.acra.2009.07.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.