MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15569845261472592

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2026

Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting.

Winter Martin, Ashraf Syed Faaz, Amabile Andrea, Devineni Neha, Kobayashi Kei, Guo Yizhan, Hasan Irsa, Kaczorowski David, Sultan Ibrahim, Bonatti Johannes

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Data on chest tube output following robotic totally endoscopic coronary artery bypass grafting (TECAB) are limited. We aimed to quantify chest tube drainage following robotic TECAB and identify factors associated with increased output.

METHODS

A total of 125 consecutive patients undergoing robotic TECAB from September 2021 to July 2025 were retrospectively analyzed. Chest tube output was recorded over 96 h postoperatively. Univariable and multivariable linear regression analyses were performed to identify predictors of increased drainage.

RESULTS

Median chest tube output over 4 days was 945 mL (interquartile range: 703 to 1,400 mL). Median chest tube duration was 3 (2 to 4) days. Drainage volumes were lower than those reported for open coronary artery bypass grafting (CABG) and comparable with mixed robotic cardiac surgery cohorts. Increased chest tube output correlated positively with the number of transfused red blood cell units (rs = 0.336, P < 0.001) and the number of postoperative chest radiographs (rs = 0.378, P < 0.001). On multivariable regression analysis, age (B = 14.2 mL/year, P = 0.049), male sex (B = 353 mL, P = 0.037), and longer procedure time (B = 1.6 mL/min, P = 0.019) were independent factors associated with increased output.

CONCLUSIONS

Chest tube output after robotic TECAB appears comparable with values reported in mixed robotic cardiac surgery and lower than those reported for open CABG. Operative strategy including single versus multivessel TECAB, arrested versus beating heart, and hybrid coronary revascularization did not significantly influence output. Chest tube output after robotic TECAB was driven by age, gender, and procedure time, and higher output was associated with higher resource use.

Для цитирования: Winter Martin, Ashraf Syed Faaz, Amabile Andrea, Devineni Neha, Kobayashi Kei, Guo Yizhan, Hasan Irsa, Kaczorowski David, Sultan Ibrahim, Bonatti Johannes. Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting.. Innovations (Philadelphia, Pa.). 2026. DOI: 10.1177/15569845261472592.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.