MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rlu.0b013e3181662f9e

Медицинская библиотека · Clinical nuclear medicine · 2008

Low-iodine diet revisited: importance in nuclear medicine imaging and management.

Hinds Sidney R, Stack Aaron L, Stocker Derek J

Клинический случайСтатьяПеревод в очереди

Аннотация

PURPOSE: The need for a low-iodine diet (LID) to maximize the results of radioactive iodine uptake (RAIU), nuclear medicine thyroid scintigraphy, and ultimately treatment of thyroid cancer patients is widely accepted. Failure to follow the prescribed diet can alter RAIU results, thyroid scan findings, and poststudy management.

OBJECTIVE

Provided is a case presentation that illustrates the need for adequate patient understanding and compliance with the LID.

METHODS

We present the clinical history, laboratory values, and pertinent imaging of a 21-year-old woman with papillary thyroid cancer. The patient's post-thyroidectomy I-123 and 2 subsequent thyroid (I-123 and post-RAI ablation I-131) scintigraphy examinations are reviewed as well as the patient's urine iodine levels.

RESULTS

In this case of a woman with papillary thyroid cancer, the nuclear medicine whole body and neck pinhole images revealed that compliance to an LID positively impacts the overall management. After an LID was followed, the patient's urine iodine level appropriately declined from the previously elevated level. Initial negative results on thyroid scintigraphy caused by noncompliance with the LID became positive when the patient adhered to the prescribed dietary regimen.

CONCLUSION

An LID is an integral element in the management of differentiated thyroid cancer. Proper guidance and emphasis on the implementation of the diet needs to be provided to patients. Noncompliance may lead to false negative imaging results, misleading the medical professionals and patient. Potentially inadequate management of the patient's thyroid cancer may follow.

Для цитирования: Hinds Sidney R, Stack Aaron L, Stocker Derek J. Low-iodine diet revisited: importance in nuclear medicine imaging and management.. Clinical nuclear medicine. 2008. DOI: 10.1097/rlu.0b013e3181662f9e.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.