Dilution-Endpoint Comparison of a Flow Cytometric Platelet Activation Assay With PF4/Heparin ELISA and a Lateral Flow Immunoassay in Suspected HIT.

Maličev Elvira, Urbajs Matjaž, Gradišar Katerina Jazbec, Kolenc Ana, Rožman Primož

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Heparin-induced thrombocytopenia (HIT) is a rare but potentially life-threatening, immune-mediated adverse reaction to heparin. PF4-dependent immunoassays are sensitive screening tests, but they detect both platelet-activating and nonactivating antibodies; therefore, positive results require interpretation in clinical context and, when available, confirmation with a functional platelet activation assay.

METHODS

We compared dilution endpoints of an in-house flow cytometric platelet activation assay with an IgG-specific PF4/polyanion ELISA and a PF4-dependent lateral flow immunoassay (LFA). Six consecutive ELISA-positive patient sera and one external ELISA-positive control serum were tested neat and in serial twofold dilutions (up to 1:2048) in parallel with all three methods. Platelet activation was assessed using platelet-rich plasma from four healthy donors in the presence of low and high doses of heparin and quantified by CD62P expression on CD61-positive platelets.

RESULTS

Five patient sera and the external control showed heparin-dependent platelet activation, whereas one ELISA-positive serum was nonactivating. All three assays were concordantly positive through dilutions up to 1:32 in platelet-activating samples. At higher dilutions, the LFA remained positive more often than the ELISA or the flow cytometric assay. Across 72 dilution points from platelet-activating sera and the external control, the ELISA was positive in 47/72, the flow assay in 51/72, and the LFA in 67/72. In several sera, mild dilution increased the ELISA signal and/or platelet activation, consistent with a prozone-like stoichiometric effect.

CONCLUSION

In this pilot dilution-series study, the in-house flow cytometric assay showed dilution endpoints broadly comparable to the IgG-specific ELISA for platelet-activating anti-PF4/heparin antibodies. The LFA remained positive at lower apparent antibody levels than either the ELISA or the functional assay, but also gave a positive result in the serum that did not contain platelet-activating anti-PF4/heparin antibodies.

Для цитирования: Maličev Elvira, Urbajs Matjaž, Gradišar Katerina Jazbec, Kolenc Ana, Rožman Primož. Dilution-Endpoint Comparison of a Flow Cytometric Platelet Activation Assay With PF4/Heparin ELISA and a Lateral Flow Immunoassay in Suspected HIT.. International journal of laboratory hematology. 2026. DOI: 10.1111/ijlh.70210.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.