MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vox.70331

Медицинская библиотека · Vox sanguinis · 2026

Comparing the volume of umbilical cord blood collection using different techniques.

van Daelen Jip H, Cortesi Valeria, Verbeek Lianne I, Cramer Sophie J E, Huisman Elise J, Klei Thomas R L, Reiss Irwin K M, Snijder Pauline M, Lopriore Enrico

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Umbilical cord blood (UCB) as a source for red blood cell (RBC) transfusions is a promising alternative to adult RBC transfusions in extremely preterm neonates, as UCB contains predominantly fetal haemoglobin (HbF). A limitation to clinical use is the low and variable yield of UCB collections. This study aimed to assess UCB collection volume and feasibility across three techniques in uncomplicated term pregnancies.

MATERIALS AND

METHODS

We conducted a prospective observational study in two centres in The Netherlands. We compared the volume of UCB units collected from uncomplicated term deliveries using three different techniques: in utero, ex utero with a funnel and ex utero with a plateau. A minimum target volume of 70 mL was deemed adequate for further processing.

RESULTS

Of 606 collection attempts, 570 (94%) were successful. The median UCB volume was 65 mL (interquartile range, IQR 49-84), with 242 (42.5%) collections ≥70 mL. Volumes differed significantly between the three techniques, with the ex utero plateau technique yielding the highest median volume (70 mL, IQR 55-88), followed by in utero (56 mL, IQR 45-71) and the funnel technique (36 mL, IQR 30-51) (p < 0.001). UCB volume correlated with birth weight (p < 0.001), but not with gestational age or sex. Volumes obtained with the plateau technique increased over time, suggesting a learning-curve effect.

CONCLUSION

Collected UCB volume was highest using the ex utero plateau technique and was associated with birth weight and operator experience. The observed learning curve underscores the importance of dedicated teams to maximize UCB collection efficiency for future transfusion use.

Для цитирования: van Daelen Jip H, Cortesi Valeria, Verbeek Lianne I, Cramer Sophie J E, Huisman Elise J, Klei Thomas R L, Reiss Irwin K M, Snijder Pauline M, Lopriore Enrico. Comparing the volume of umbilical cord blood collection using different techniques.. Vox sanguinis. 2026. DOI: 10.1111/vox.70331.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.