Diagnosing metal fume fever--an integrated approach.

Cain J R, Fletcher R M

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Exposure to high concentrations of zinc oxide fume can cause metal fume fever (MFF). Two cases occurring following the oxy-acetylene cutting of galvanized steel frames are reported.

AIMS: To show that integrated working is valuable as secondary health care staff may not be familiar with MFF.

METHODS

Site visits by Her Majesty's Medical, Health and Safety (H&S) and Specialist Occupational Hygiene Inspectors to gather information and cooperation with occupational health, primary and secondary health care staff to diagnose MFF.

RESULTS

Poor exposure control caused metal fume inhalation in these cases. Multidisciplinary working established diagnosis, causation and compliance with H&S legislation.

CONCLUSIONS

Risk assessments are required to identify health risks and to determine required exposure control measures. Failure to do this resulted in an unusual case of MFF leading to hospital admission. Diagnosis can be delayed if a full occupational history is not taken. Successful investigation of such cases benefits from collaborative working.

Для цитирования: Cain J R, Fletcher R M. Diagnosing metal fume fever--an integrated approach.. Occupational medicine (Oxford, England). 2010. DOI: 10.1093/occmed/kqq036.