MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.snb.2023.133950

Медицинская библиотека · Sensors and actuators. B, Chemical · 2023

MASTR Pouch: Palm-size lab for point-of-care detection of Mpox using recombinase polymerase amplification and CRISPR technology.

Wei Jia, Wang Wanjun, Yu Qiong, Zhang Mingrui, Xue Fengyu, Fan Beibei, Zhang Tong, Gao Yanpeng, Li Juan, Meng Xianying, Pang Bo

СтатьяПеревод в очереди

Аннотация

Mpox (formerly referred as Monkeypox) outbreak has been declared a Public Health Emergency of International Concern. However, traditional polymerase chain reaction (PCR) diagnostic technology is not ideal for on-site applications. To conduct the sample-to-result Mpox viral particles detection outside the laboratories, we developed an easy-to-operate palm-size pouch, termed Mpox At-home Self-Test and point-of-caRe Pouch (MASTR Pouch). In this MASTR Pouch, the fast and accurate visualization was achieved by incorporating recombinase polymerase amplification (RPA) with clustered regularly interspaced short palindromic repeat (CRISPR)/Cas12a system. From viral particle lysis to naked eye readout, MASTR Pouch required only four simple steps to accomplish the analysis process within 35 min. Fifty-three Mpox pseudo-viral particles in exudate (10.6 particles/μL) were able to be detected. To verify the practicability, 104 mock Mpox clinical exudate specimens were tested. The clinical sensitivities were determined to be 91.7%- 95.8%. There was no false-positive result, validating the 100% clinical specificity. MASTR Pouch approaches the WHO's ASSURD criteria for point-of-care diagnostic, which will be beneficial for mitigating Mpox's global spread. The versatility potential of MASTR Pouch could further revolutionize infection diagnosis.

Для цитирования: Wei Jia, Wang Wanjun, Yu Qiong, Zhang Mingrui, Xue Fengyu, Fan Beibei, Zhang Tong, Gao Yanpeng, Li Juan, Meng Xianying, Pang Bo. MASTR Pouch: Palm-size lab for point-of-care detection of Mpox using recombinase polymerase amplification and CRISPR technology.. Sensors and actuators. B, Chemical. 2023. DOI: 10.1016/j.snb.2023.133950.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.